Abstract

Total hip arthroplasty (THA) has been performed for nearly 50 years. Between 2006 and 2012, more than 600,000 metal-on-metal THA procedures were performed in the United States. This article reviews the production of metal wear debris in a metal-on-metal articulation and the interaction of cobalt and chromium ions that ultimately led to a dramatic decline in the use of metal-on-metal THA articulations. Additionally, the article reviews mechanisms of metal wear, the biologic reaction to cobalt and chromium ions, the clinical presentation of failing metal-on-metal articulations, and current diagnostic strategies. Further, the article discusses the use of inflammatory markers, metal ion levels, radiographs, metal artifact reduction sequence magnetic resonance imaging, and ultrasound for failed metal-on-metal THA procedures. When adopting new technologies, orthopedic surgeons must weigh the potential increased benefits against the possibility of new mechanisms of failure. Metal-on-metal bearings are a prime example of the give and take between innovation and clinical results, especially in the setting of an already successful procedure such as THA. [Orthopedics. 2016; 39(6):371-379.].

Citing Articles

The Performance of Primary Dual-Mobility Total Hip Arthroplasty in Patients Aged 55 Years and Younger: A Systematic Review.

Heifner J, Keller L, Fox Y, Sakalian P, Corces A Arthroplast Today. 2023; 24:101241.

PMID: 38023650 PMC: 10661692. DOI: 10.1016/j.artd.2023.101241.


Hyaluronic acid-British anti-Lewisite as a safer chelation therapy for the treatment of arthroplasty-related metallosis.

Ude C, Schmidt S, Laurencin S, Shah S, Esdaille J, Kan H Proc Natl Acad Sci U S A. 2023; 120(45):e2309156120.

PMID: 37903261 PMC: 10636327. DOI: 10.1073/pnas.2309156120.


Translational Characterization of Macrophage Responses to Stable and Non-Stable CoCrMo Wear and Corrosion Debris Generated In-Situ for Total Hip Replacement.

Ebinger K, Samelko L, Radice S, Hallab N, Wimmer M Biotribology (Oxf). 2023; 35-36.

PMID: 37900899 PMC: 10611437. DOI: 10.1016/j.biotri.2023.100259.


Cross-sectional association between systemic metal concentrations and immune markers in patients with total joint arthroplasty.

Peterson S, OByrne T, Brennan P, Jannetto P, Pavelko K, Lewallen D Front Immunol. 2023; 14:1130209.

PMID: 36993965 PMC: 10040609. DOI: 10.3389/fimmu.2023.1130209.


Interaction of Ceramic Implant Materials with Immune System.

Rafikova G, Piatnitskaia S, Shapovalova E, Chugunov S, Kireev V, Ialiukhova D Int J Mol Sci. 2023; 24(4).

PMID: 36835610 PMC: 9959507. DOI: 10.3390/ijms24044200.