Utility of Equilibrium Radionuclide Angiogram-Derived Measures of Dyssynchrony to Predict Outcomes in Heart Failure Patients Undergoing Cardiac Resynchronization Therapy

Overview
Journal J Nucl Med
Specialty Nuclear Medicine
Date 2016 Jul 16
PMID 27417646
Citations 11
Authors
Affiliations
Soon will be listed here.
Abstract

Methods: Sixty-six advanced heart failure patients referred for CRT with an LV ejection fraction (EF) of < 35% and QRS ≥ 120 ms were studied. We performed equilibrium radionuclide angiography (ERNA) before and 6 mo after CRT. We assessed ventricular dyssynchrony with parameters derived from the first harmonic phase (Ø) analysis of the ERNA time-activity curve and evaluated change in these parameters after 6 mo of CRT. These parameters include novel indices of synchrony (S), a measure of intraventricular contraction order, and entropy (E), a measure of intraventricular contraction disorder, and interventricular synchrony (IVS), a measure of synchronous biventricular function.

Results: Forty-seven (71%) patients improved clinically (responders) at 6 mo after CRT whereas 19 (28.8%) showed no change in New York Heart Association class or worsened (nonresponders). The post-CRT changes in QRS duration (P = 0.006), echocardiographic (P = 0.03) and ERNA LVEF (P = 0.0007), LVS (P = 0.004), LVE (P = 0.006), LV standard deviation of ventricular phase (LVSDØ) (P = 0.004), and IVS (P = 0.05) were significantly different between responders and nonresponders. Sixty-two percent of responders had either an LVS < 0.84 or an IVS ≥ 18.8° as opposed to only 16% of nonresponders (P = 0.001). Twenty-nine of 32 (91%) patients with either of these measures responded to CRT (P < 0.01).

Conclusion: LVS and IVS are novel measures of LV dyssynchrony derived from ERNA planar analysis. A baseline value of LVS < 0.84 or IVS ≥ 18.8° predicts a positive response to CRT.

Citing Articles

Cardiotoxicity detection tool for breast cancer chemotherapy: a retrospective study.

Alenezi A, McKiddie F, Nath M, Mayya A, Welch A PeerJ Comput Sci. 2024; 12:e2230.

PMID: 39144824 PMC: 11323080. DOI: 10.7717/peerj-cs.2230.


Effect of short-term cardiac function changes after cardiac resynchronization therapy on long-term prognosis in heart failure patients with and without diabetes.

Yu Y, Ding L, Huang H, Cheng S, Deng Y, Cai C Ther Adv Chronic Dis. 2024; 15:20406223231223285.

PMID: 38250742 PMC: 10798070. DOI: 10.1177/20406223231223285.


Beta-blockers and mechanical dyssynchrony in heart failure assessed by radionuclide ventriculography.

Jones K, Paterson C, Ray S, Motherwell D, Hamilton D, Small A J Nucl Cardiol. 2022; 30(1):193-200.

PMID: 36417121 PMC: 9984517. DOI: 10.1007/s12350-022-03142-x.


Single-photon cardiac imaging in patients with cardiac implantable electrical devices.

Valzania C, Bonfiglioli R, Fallani F, Martignani C, Ziacchi M, Diemberger I J Nucl Cardiol. 2020; 29(2):633-641.

PMID: 33241474 DOI: 10.1007/s12350-020-02436-2.


Intraventricular synchronism assessment by gated-SPECT myocardial perfusion imaging in cardiac resynchronization therapy. Does cardiomyopathy type influence results?.

Peix A, Padron K, Cabrera L, Castaneda O, Milan D, Castro J EJNMMI Res. 2020; 10(1):125.

PMID: 33079263 PMC: 7575672. DOI: 10.1186/s13550-020-00703-4.