» Articles » PMID: 27409528

Accelerated Biofluid Filling in Complex Microfluidic Networks by Vacuum-Pressure Accelerated Movement (V-PAM)

Overview
Journal Small
Date 2016 Jul 14
PMID 27409528
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

Rapid fluid transport and exchange are critical operations involved in many microfluidic applications. However, conventional mechanisms used for driving fluid transport in microfluidics, such as micropumping and high pressure, can be inaccurate and difficult for implementation for integrated microfluidics containing control components and closed compartments. Here, a technology has been developed termed Vacuum-Pressure Accelerated Movement (V-PAM) capable of significantly enhancing biofluid transport in complex microfluidic environments containing dead-end channels and closed chambers. Operation of the V-PAM entails a pressurized fluid loading into microfluidic channels where gas confined inside can rapidly be dissipated through permeation through a thin, gas-permeable membrane sandwiched between microfluidic channels and a network of vacuum channels. Effects of different structural and operational parameters of the V-PAM for promoting fluid filling in microfluidic environments have been studied systematically. This work further demonstrates the applicability of V-PAM for rapid filling of temperature-sensitive hydrogels and unprocessed whole blood into complex irregular microfluidic networks such as microfluidic leaf venation patterns and blood circulatory systems. Together, the V-PAM technology provides a promising generic microfluidic tool for advanced fluid control and transport in integrated microfluidics for different microfluidic diagnosis, organs-on-chips, and biomimetic studies.

Citing Articles

A microfluidics-based stem cell model of early post-implantation human development.

Zheng Y, Shao Y, Fu J Nat Protoc. 2020; 16(1):309-326.

PMID: 33311712 DOI: 10.1038/s41596-020-00417-w.


An easy-to-build and re-usable microfluidic system for live-cell imaging.

Babic J, Griscom L, Cramer J, Coudreuse D BMC Cell Biol. 2018; 19(1):8.

PMID: 29925307 PMC: 6011407. DOI: 10.1186/s12860-018-0158-z.


Centrifugal microfluidics for sorting immune cells from whole blood.

Yu Z, Joseph J, Liu S, Cheung M, Haffey P, Kurabayashi K Sens Actuators B Chem. 2017; 245:1050-1061.

PMID: 28966475 PMC: 5619665. DOI: 10.1016/j.snb.2017.01.113.


Hydrophilic Sponges for Leaf-Inspired Continuous Pumping of Liquids.

Zhou T, Yang J, Zhu D, Zheng J, Handschuh-Wang S, Zhou X Adv Sci (Weinh). 2017; 4(6):1700028.

PMID: 28638785 PMC: 5473324. DOI: 10.1002/advs.201700028.

References
1.
Yu Z, Aw Yong K, Fu J . Microfluidic blood cell sorting: now and beyond. Small. 2014; 10(9):1687-703. PMC: 4013196. DOI: 10.1002/smll.201302907. View

2.
Hu W, Berdugo C, Chalmers J . The potential of hydrodynamic damage to animal cells of industrial relevance: current understanding. Cytotechnology. 2011; 63(5):445-60. PMC: 3176934. DOI: 10.1007/s10616-011-9368-3. View

3.
Chung B, Park J, Hu J, Huang C, Monuki E, Jeon N . A hybrid microfluidic-vacuum device for direct interfacing with conventional cell culture methods. BMC Biotechnol. 2007; 7:60. PMC: 2071914. DOI: 10.1186/1472-6750-7-60. View

4.
Unger M, Chou H, Thorsen T, Scherer A, Quake S . Monolithic microfabricated valves and pumps by multilayer soft lithography. Science. 2001; 288(5463):113-6. DOI: 10.1126/science.288.5463.113. View

5.
Lukashev M, Werb Z . ECM signalling: orchestrating cell behaviour and misbehaviour. Trends Cell Biol. 1998; 8(11):437-41. DOI: 10.1016/s0962-8924(98)01362-2. View