» Articles » PMID: 27391501

Evaluation of Optic Canal and Surrounding Structures Using Cone Beam Computed Tomography: Considerations for Maxillofacial Surgery

Overview
Date 2016 Jul 9
PMID 27391501
Citations 9
Authors
Affiliations
Soon will be listed here.
Abstract

The optic canal connects the anterior cranial fossa and the orbit and maintains the optic nerve and the ophthalmic artery. Within the extent of the surgical approach of the region, risk of iatrogenic injury of the neural and vascular structures increases. The aim of this retrospective morphometric study is to investigate the radiological anatomy of orbita, optic canal, and its surrounding using cone beam computed tomography (CBCT) scans in a group of Turkish population.Cone beam computed tomography images of a total of 182 patients were evaluated by 2 observers. Anatomical parameters regarding optic canal and orbita were measured for all patients from axial, sagittal, and three-dimensional reconstructed images. To assess intraobserver reliability, the Wilcoxon matched-pairs test was used. Pearson χ test and Student t test were performed for statistical analysis of differences, sex, localization, and measurements (P < 0.05).Repeated CBCT evaluation and measurements indicated no significant inter and intra-observer difference were found (P > 0.05). The orbita width and height were larger for the males than females (P < 0.05). No significant difference was observed for optic canal shape, dimensions of infraorbital foramen (IOF) and supraorbital foramen (SOF), SOF-midline distance, and SOF-IOF distance according to sex and location (P > 0.05). Examination CBCT scans revealed that the shape of the optic canal was 70% funnel and 28% Hourglass shape, 2% amorph type round.These results provide detailed knowledge of the anatomical characteristics in the orbital area which may be of assistance for surgeons preoperatively. Cone beam computed tomography scans can be an alternative modality for multislice computed tomography with submillimeter resolution and lower dose in preoperative imaging of the orbit.

Citing Articles

Evaluation of the location of posterior superior alveolar artery and infraorbital foramen originating from the same source by using cone beam computed tomography.

Cam K, Zengin A BMC Oral Health. 2025; 25(1):105.

PMID: 39833738 PMC: 11748275. DOI: 10.1186/s12903-024-05408-x.


Comparative Study of Computerized Tomography Imaging of Facial Trauma Using 2D and 3D Reconstruction Scans.

Kv A, Kc S Cureus. 2024; 16(7):e65217.

PMID: 39184623 PMC: 11341213. DOI: 10.7759/cureus.65217.


Morphometric evaluation of the anatomical relationships between the superior orbital fissure and the orbital structures based on computed tomography images with clinical implications.

Erbek E, Cicekcibasi A, Acar G, Digilli Ayas B, Aydogdu D Int Ophthalmol. 2024; 44(1):267.

PMID: 38913238 DOI: 10.1007/s10792-024-03196-5.


[Applications of cone beam computed tomography of the craneofacial structure in medical specialties. A review].

Munoz-Galvan A, Fiori-Chincaro G, Agudelo-Botero A Rev Cient Odontol (Lima). 2024; 10(1):e100.

PMID: 38389916 PMC: 10880726. DOI: 10.21142/2523-2754-1001-2022-100.


Three-Dimensional (3D) Analysis of Orbital Morphometry in Healthy Anatolian Adults: Sex, Side Discrepancies, and Clinical Relevance.

Erdem H, Tekeli M, Cevik Y, Kilic Safak N, Kaya O, Boyan N Cureus. 2023; 15(9):e45208.

PMID: 37842472 PMC: 10576211. DOI: 10.7759/cureus.45208.