» Articles » PMID: 27386475

Pathologic Evaluation of a New Endoscopic Ultrasound Needle Designed to Obtain Core Tissue Samples: A Pilot Study

Overview
Date 2016 Jul 8
PMID 27386475
Citations 22
Authors
Affiliations
Soon will be listed here.
Abstract

Background And Objectives: Standard endoscopic ultrasound-fine-needle aspiration (EUS-FNA) needles are in widespread use. Meaningful differences between the available needles have been difficult to identify. Recently, a new EUS needle (Shark Core®, Covidien, Dublin, Leinster, Ireland), has been introduced in an attempt to improve diagnostic accuracy, tissue yield, and to potentially obtain a core tissue sample. We performed a pilot study prospectively to evaluate this new needle when compared to a standard EUS-FNA needle.

Materials And Methods: Analysis of the first 15 patients undergoing EUS-FNA with the Shark Core needle was performed and it was compared to EUS-FNA in 15 patients who underwent EUS-FNA with a standard needle.

Results: The Shark Core needle required fewer needle passes to obtain diagnostic adequacy than the standard needle [(χ(2)(1) = 11.3, P < 0.001]. The Shark Core needle required 1.5 passes to reach adequacy, whereas the standard needle required three passes. For cases with cell blocks, the Shark Core needle produced diagnostic material in 85% of cases [95% confidence interval (CI): 54-98], whereas the standard needle produced diagnostic material in 38% of the cases (95% CI: 9-76). The Shark Core needle produced actual tissue cores 82% of the time (95% CI: 48-98) and the standard needle produced no tissue cores (95% CI: 0-71) (P = 0.03).

Conclusion: This pilot study found that the Shark Core needle had a high rate of producing adequate cytologic material for the diagnosis of pancreatic and peri-pancreatic lesions sampled by EUS with fewer passes required to obtain a definitive diagnosis and with a high rate of tissue cores being obtained when compared to a standard FNA needle.

Citing Articles

The history of endoscopic ultrasound-guided fine-needle aspiration: development and progress.

Kanno A, Ikeda E, Ando K, Yokoyama K, Yamamoto H J Med Ultrason (2001). 2024; 51(2):187-194.

PMID: 38244112 DOI: 10.1007/s10396-023-01400-0.


Current status of molecular diagnostic approaches using liquid biopsy.

Takahashi K, Takeda Y, Ono Y, Isomoto H, Mizukami Y J Gastroenterol. 2023; 58(9):834-847.

PMID: 37470859 PMC: 10423147. DOI: 10.1007/s00535-023-02024-4.


Deep learning for real-time auxiliary diagnosis of pancreatic cancer in endoscopic ultrasonography.

Tian G, Xu D, He Y, Chai W, Deng Z, Cheng C Front Oncol. 2022; 12:973652.

PMID: 36276094 PMC: 9586286. DOI: 10.3389/fonc.2022.973652.


Comparison of Fork-tip and Franseen needles for endoscopic ultrasound-guided fine-needle biopsy in pancreatic solid lesions: A propensity-matched analysis.

Fujita A, Ryozawa S, Tanisaka Y, Ogawa T, Saito Y, Katsuda H DEN Open. 2022; 3(1):e147.

PMID: 35898843 PMC: 9307731. DOI: 10.1002/deo2.147.


Performance of EUS-FNB in solid pancreatic masses: a lesson from 463 consecutive procedures and a practical nomogram.

Pagano N, Ricci C, Ingaldi C, Sadalla S, Fabbri A, Alberici L Updates Surg. 2021; 74(3):945-952.

PMID: 34714535 DOI: 10.1007/s13304-021-01198-x.


References
1.
Kim J, Lee S, Moon S, Kim H, Kim H, Song I . Incremental value of cell block preparations over conventional smears alone in the evaluation of EUS-FNA for pancreatic masses. Hepatogastroenterology. 2015; 61(135):2117-22. View

2.
Kipp B, Pereira T, Souza P, Gleeson F, Levy M, Clayton A . Comparison of EUS-guided FNA and Trucut biopsy for diagnosing and staging abdominal and mediastinal neoplasms. Diagn Cytopathol. 2009; 37(8):549-56. DOI: 10.1002/dc.21042. View

3.
Gimeno-Garcia A, Paquin S, Gariepy G, Jimenez Sosa A, Sahai A . Comparison of endoscopic ultrasonography-guided fine-needle aspiration cytology results with and without the stylet in 3364 cases. Dig Endosc. 2013; 25(3):303-7. DOI: 10.1111/j.1443-1661.2012.01374.x. View

4.
Songur N, Songur Y, Bircan S, Kapucuoglu N . Comparison of 19- and 22-gauge needles in EUS-guided fine needle aspiration in patients with mediastinal masses and lymph nodes. Turk J Gastroenterol. 2012; 22(5):472-8. DOI: 10.4318/tjg.2011.0322. View

5.
Wani S, Gupta N, Gaddam S, Singh V, Ulusarac O, Romanas M . A comparative study of endoscopic ultrasound guided fine needle aspiration with and without a stylet. Dig Dis Sci. 2011; 56(8):2409-14. DOI: 10.1007/s10620-011-1608-z. View