» Articles » PMID: 27372275

Field Evaluation of a Random Forest Activity Classifier for Wrist-worn Accelerometer Data

Overview
Journal J Sci Med Sport
Specialty Orthopedics
Date 2016 Jul 4
PMID 27372275
Citations 55
Authors
Affiliations
Soon will be listed here.
Abstract

Objectives: Wrist-worn accelerometers are convenient to wear and associated with greater wear-time compliance. Previous work has generally relied on choreographed activity trials to train and test classification models. However, validity in free-living contexts is starting to emerge. Study aims were: (1) train and test a random forest activity classifier for wrist accelerometer data; and (2) determine if models trained on laboratory data perform well under free-living conditions.

Design: Twenty-one participants (mean age=27.6±6.2) completed seven lab-based activity trials and a 24h free-living trial (N=16).

Methods: Participants wore a GENEActiv monitor on the non-dominant wrist. Classification models recognising four activity classes (sedentary, stationary+, walking, and running) were trained using time and frequency domain features extracted from 10-s non-overlapping windows. Model performance was evaluated using leave-one-out-cross-validation. Models were implemented using the randomForest package within R. Classifier accuracy during the 24h free living trial was evaluated by calculating agreement with concurrently worn activPAL monitors.

Results: Overall classification accuracy for the random forest algorithm was 92.7%. Recognition accuracy for sedentary, stationary+, walking, and running was 80.1%, 95.7%, 91.7%, and 93.7%, respectively for the laboratory protocol. Agreement with the activPAL data (stepping vs. non-stepping) during the 24h free-living trial was excellent and, on average, exceeded 90%. The ICC for stepping time was 0.92 (95% CI=0.75-0.97). However, sensitivity and positive predictive values were modest. Mean bias was 10.3min/d (95% LOA=-46.0 to 25.4min/d).

Conclusions: The random forest classifier for wrist accelerometer data yielded accurate group-level predictions under controlled conditions, but was less accurate at identifying stepping verse non-stepping behaviour in free living conditions Future studies should conduct more rigorous field-based evaluations using observation as a criterion measure.

Citing Articles

Minimum and optimal combined variations in sleep, physical activity, and nutrition in relation to all-cause mortality risk.

Stamatakis E, Koemel N, Biswas R, Ahmadi M, Allman-Farinelli M, Trost S BMC Med. 2025; 23(1):111.

PMID: 40001093 PMC: 11863424. DOI: 10.1186/s12916-024-03833-x.


Device-Measured Physical Activity, Sedentary Behaviour and Risk of Chronic Kidney Diseases Across Levels of Grip Strength.

He Y, Wang J, Zhang W, Chen X, Wu Q, Li Y J Cachexia Sarcopenia Muscle. 2025; 16(1):e13726.

PMID: 39957059 PMC: 11830631. DOI: 10.1002/jcsm.13726.


Analytical Validation of Wrist-Worn Accelerometer-Based Step-Count Methods during Structured and Free-Living Activities.

Marcotte R, Bachman S, Zhai Y, Clay I, Lyden K Digit Biomark. 2025; 9(1):10-22.

PMID: 39872700 PMC: 11771982. DOI: 10.1159/000542850.


Identification of potential biomarkers from amino acid transporter in the activation of hepatic stellate cells via bioinformatics.

Zhao Y, Xu X, Cai H, Wu W, Wang Y, Huang C Front Genet. 2024; 15:1499915.

PMID: 39698464 PMC: 11652522. DOI: 10.3389/fgene.2024.1499915.


Physical Activity Outcomes of a Culturally Tailored, Father-Focused, and Family-Centered Health Promotion Program for Mexican-Heritage Families: (Make Room for Daddy).

Umstattd Meyer M, Prochnow T, Wende M, Ylitalo K, Sturdivant R, Johnson C Int J Environ Res Public Health. 2024; 21(11).

PMID: 39595744 PMC: 11593588. DOI: 10.3390/ijerph21111475.