Transverse Relaxation and Flip Angle Mapping: Evaluation of Simultaneous and Independent Methods Using Multiple Spin Echoes

Overview
Journal Magn Reson Med
Publisher Wiley
Specialty Radiology
Date 2016 Jul 2
PMID 27367906
Citations 15
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To evaluate transverse relaxation (T2) and flip angle maps derived from signal pathway modeling of multiple spin echoes using simultaneous or independent T2 and flip angle fitting.

Methods: We examined different approaches to indirect and stimulated echo compensated T2 relaxometry from multiple spin echoes to evaluate both T2 and flip angle accuracy in simulation, phantom, and human brain. Signal pathways were modeled with or without independent flip angle maps using either Bloch simulations, or Extended Phase Graph (EPG) with Fourier or Shinnar-Le Roux approximation of slice profiles.

Results: Slice-selective decay curves differ substantially between models. Inaccurate flip angles are obtained with EPG methods, although T2 values are relatively accurate. Providing measured flip angles to EPG methods yields erroneous T2. Bloch methods improve both T2 and flip angle results. Simultaneous fitting can suffer from flip angle redundancy yielding multiple T2 solutions, particularly in low signal-to-noise ratio cases.

Conclusion: EPG fitting provides reasonably accurate T2, but is limited by poor accuracy in resulting flip angles, and T2 errors increase when flip angles are provided. Bloch simultaneous fitting of T2 and flip angle provides excellent results, but can be limited by multiple solutions which can be overcome by including a flip angle map. Magn Reson Med 77:2057-2065, 2017. © 2016 International Society for MagneticResonance in Medicine.

Citing Articles

Longitudinal hippocampal diffusion-weighted imaging and T2 relaxometry demonstrate regional abnormalities which are stable and predict subfield pathology in temporal lobe epilepsy.

Adel S, Treit S, Abd Wahab W, Little G, Schmitt L, Wilman A Epilepsia Open. 2022; 8(1):100-112.

PMID: 36461649 PMC: 9977756. DOI: 10.1002/epi4.12679.


Correcting for imaging gradients-related bias of T relaxation times at high-resolution MRI.

Bnaiahu N, Omer N, Wilczynski E, Levy S, Blumenfeld-Katzir T, Ben-Eliezer N Magn Reson Med. 2022; 88(4):1806-1817.

PMID: 35666831 PMC: 9544944. DOI: 10.1002/mrm.29319.


Myelin water fraction mapping from multiple echo spin echoes and an independent B map.

Mehdizadeh N, Wilman A Magn Reson Med. 2022; 88(3):1380-1390.

PMID: 35576121 PMC: 9321077. DOI: 10.1002/mrm.29286.


T quantification in brain using 3D fast spin-echo imaging with long echo trains.

Snyder J, McPhee K, Wilman A Magn Reson Med. 2021; 87(5):2145-2160.

PMID: 34894641 PMC: 9299830. DOI: 10.1002/mrm.29113.


A unifying view on extended phase graphs and Bloch simulations for quantitative MRI.

Guenthner C, Amthor T, Doneva M, Kozerke S Sci Rep. 2021; 11(1):21289.

PMID: 34711847 PMC: 8553818. DOI: 10.1038/s41598-021-00233-6.