» Articles » PMID: 27365032

Non-antibody Protein-based Biosensors

Overview
Journal Essays Biochem
Specialty Biochemistry
Date 2016 Jul 2
PMID 27365032
Citations 13
Authors
Affiliations
Soon will be listed here.
Abstract

Biosensors that depend on a physical or chemical measurement can be adversely affected by non-specific interactions. For example, a biosensor designed to measure specifically the levels of a rare analyte can give false positive results if there is even a small amount of interaction with a highly abundant but irrelevant molecule. To overcome this limitation, the biosensor community has frequently turned to antibody molecules as recognition elements because they are renowned for their exquisite specificity. Unfortunately antibodies can often fail when immobilised on inorganic surfaces, and alternative biological recognition elements are needed. This article reviews the available non-antibody-binding proteins that have been successfully used in electrical and micro-mechanical biosensor platforms.

Citing Articles

Dynamic Addressing Molecular Robot (DAMR): An Effective and Efficient Trial-and-Error Approach for the Analysis of Single Nucleotide Polymorphisms.

Chen T, Chen G, Cao S, Tang X, Li W, Liu C Adv Sci (Weinh). 2024; 11(31):e2402140.

PMID: 38884120 PMC: 11336946. DOI: 10.1002/advs.202402140.


Avidity-based biosensors for ubiquitylated PCNA reveal choreography of DNA damage bypass.

Yakoub G, Choi Y, Wong R, Strauch T, Ann K, Cohen R Sci Adv. 2023; 9(36):eadf3041.

PMID: 37672592 PMC: 10482348. DOI: 10.1126/sciadv.adf3041.


Bioaffinity Nanoprobes for Foodborne Pathogen Sensing.

Bruce-Tagoe T, Danquah M Micromachines (Basel). 2023; 14(6).

PMID: 37374709 PMC: 10301367. DOI: 10.3390/mi14061122.


Duplex On-Site Detection of and by Recombinase Polymerase Amplification and Three-Segment Lateral Flow Strips.

Wang P, Liao L, Ma C, Zhang X, Yu J, Yi L Biosensors (Basel). 2021; 11(5).

PMID: 34066017 PMC: 8151630. DOI: 10.3390/bios11050151.


Applications, challenges, and needs for employing synthetic biology beyond the lab.

Brooks S, Alper H Nat Commun. 2021; 12(1):1390.

PMID: 33654085 PMC: 7925609. DOI: 10.1038/s41467-021-21740-0.


References
1.
Patris S, De Pauw P, Vandeput M, Huet J, Van Antwerpen P, Muyldermans S . Nanoimmunoassay onto a screen printed electrode for HER2 breast cancer biomarker determination. Talanta. 2014; 130:164-70. DOI: 10.1016/j.talanta.2014.06.069. View

2.
Woodman R, Yeh J, Laurenson S, Ko Ferrigno P . Design and validation of a neutral protein scaffold for the presentation of peptide aptamers. J Mol Biol. 2005; 352(5):1118-33. DOI: 10.1016/j.jmb.2005.08.001. View

3.
Davis J, Tkac J, Laurenson S, Ko Ferrigno P . Peptide aptamers in label-free protein detection: 1. Characterization of the immobilized scaffold. Anal Chem. 2007; 79(3):1089-96. DOI: 10.1021/ac061863z. View

4.
Cheley S, Xie H, Bayley H . A genetically encoded pore for the stochastic detection of a protein kinase. Chembiochem. 2006; 7(12):1923-7. DOI: 10.1002/cbic.200600274. View

5.
Johnson A, Song Q, Ko Ferrigno P, Bueno P, Davis J . Sensitive affimer and antibody based impedimetric label-free assays for C-reactive protein. Anal Chem. 2012; 84(15):6553-60. DOI: 10.1021/ac300835b. View