» Articles » PMID: 27364796

Magnetic Resonance Three-dimensional Cube Technique in the Measurement of Piglet Femoral Anteversion

Overview
Specialty General Medicine
Date 2016 Jul 2
PMID 27364796
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

Background: The accurate measurement of the femoral anteversion (FA) angle is always a topic of much debate in the orthopedic surgery and radiology research. We aimed to explore a new FA measurement method to acquire accurate results without radiation damage using piglet model.

Methods: A total of thirty piglets were assigned to two groups based on the age. Bilateral femora were imaged with 3.0-T magnetic resonance (MR) and 64-slice computed tomography (CT) examinations on all piglets. FA was measured on MR-three-dimensional (3D) postprocessing software with a four-step method: initial validation of the femoral condylar axis, validation of the condylar plane, validation of the femoral neck axis, and line-plane angle measurement of FA. After MR and CT examinations, all piglets were sacrificed and their degree of FA was measured using their excised, dried femora. MR, CT, and dried-femur measurement results were analyzed statistically; MR and CT measurements were compared for accuracy against each other and against the gold standard dried femur measurement.

Results: In both groups, the mean FA value measured by MR was lower than that measured by CT. A statistically significant difference was observed between CT- and dried-femur measurements but not between MR- and dried-femur measurements. A higher correlation (0.783 vs. 0.408) and a higher consistency (0.863 vs. 0.578) with dried-femur measurement results were seen for MR measurements than CT measurements in the 1-week age group. However, in the 8-week age group, similar correlations (0.707 vs. 0.669) and consistencies (0.864 vs. 0.821) were observed.

Conclusions: Noninvasive MR-3D-Cube reconstruction was able to accurately measure FA in piglets. Particularly in the 1-week age group with a larger proportion of cartilaginous structures, the correlation and consistency between MR- and dried-femur measurement results were higher than those between CT- and dried-femur measurements, suggesting that MR may be a new useful examination tool for FA-related diseases in children.

Citing Articles

Application Value of a Novel Micro-Coil in High-Resolution Imaging of Experimental Mice Based on 3.0 T Clinical MR.

Qiu X, Liu Y, Lv F Tomography. 2024; 10(6):839-847.

PMID: 38921941 PMC: 11209402. DOI: 10.3390/tomography10060064.

References
1.
Chhabra A, Nordeck S, Wadhwa V, Madhavapeddi S, Robertson W . Femoroacetabular impingement with chronic acetabular rim fracture - 3D computed tomography, 3D magnetic resonance imaging and arthroscopic correlation. World J Orthop. 2015; 6(6):498-504. PMC: 4501936. DOI: 10.5312/wjo.v6.i6.498. View

2.
Dunn P, Gardiner H . Screening for congenital dislocation of the hip. Lancet. 1991; 337(8749):1096-7. DOI: 10.1016/0140-6736(91)91743-e. View

3.
Park T, Park S, Kim J, Kim I, Kim S . Measurement of femoral neck anteversion in 3D. Part 1: 3D imaging method. Med Biol Eng Comput. 2001; 38(6):603-9. DOI: 10.1007/BF02344864. View

4.
Prasad S, Bruce C, Crawford S, Higham J, Garg N . Femoral anteversion in infants: a method using ultrasound. Skeletal Radiol. 2003; 32(8):462-7. DOI: 10.1007/s00256-003-0652-y. View

5.
Tonnis D, Heinecke A . Acetabular and femoral anteversion: relationship with osteoarthritis of the hip. J Bone Joint Surg Am. 1999; 81(12):1747-70. DOI: 10.2106/00004623-199912000-00014. View