» Articles » PMID: 27352275

Assessment of the Minimum Clinically Important Difference in the Timed Up and Go Test After Surgery for Lumbar Degenerative Disc Disease

Overview
Journal Neurosurgery
Specialty Neurosurgery
Date 2016 Jun 29
PMID 27352275
Citations 45
Authors
Affiliations
Soon will be listed here.
Abstract

Background: The Timed Up and Go Test (TUG Test) has previously been described as a reliable tool to evaluate objective functional impairment in patients with degenerative disc disease.

Objective: The aim of this study was to assess the minimum clinically important difference (MCID) of the TUG Test.

Methods: The TUG Test (measured in seconds) was correlated with validated patient-reported outcome measures (PROs) of pain intensity (Visual Analog Scale for back and leg pain), functional impairment (Oswestry Disability Index, Roland Morris Disability Index), and health-related quality of life measures (Short Form-12 and EuroQol 5D). Three established methods were used to establish anchor-based MCID values using responders of the following PROs (Visual Analog Scale back and leg pain, Oswestry Disability Index, Roland Morris Disability Index, EuroQol 5D index, and Short Form-12 Physical Component Summary) as anchors: (1) average change, (2) minimum detectable change, and (3) change difference approach.

Results: One hundred patients with a mean ± SD age of 56.2 ± 16.1 years, 57 (57%) male, 45 patients undergoing microdiscectomy, 35 undergoing lumbar decompression, and 20 undergoing fusion surgery were studied. The 3 MCID computation methods revealed a range of MCID values according to the PRO used from 0.9 s (Oswestry Disability Index based on the change difference approach) to 6.0 s (EuroQol 5D index based on the minimum detectable change approach), with a mean MCID of 3.4 s for all measured PROs.

Conclusion: The MCID for the TUG Test time is highly variable depending on the computation technique used. The average TUG Test MCID was 3.4 s using all 3 methods and all anchors.

Citing Articles

Development and Implementation of Strong Foundations, a Digitally Delivered Fall Prevention Program: Usability and Feasibility Pilot Exercise Cohort Study.

Moran R, Wing D, Davey H, Barkai H, Nichols J JMIR Form Res. 2025; 9:e67406.

PMID: 40019778 PMC: 11887584. DOI: 10.2196/67406.


Direct anterior and direct lateral approach in patients with femoral neck fractures receiving a total hip arthroplasty: a randomized controlled trial.

Hoseth J, Aae T, Lian O, Myklebust T, Husby O Acta Orthop. 2025; 96():73-79.

PMID: 39804816 PMC: 11726854. DOI: 10.2340/17453674.2025.42847.


Reliability of self-measured objective functional impairment using the timed up and go test in patients with diseases of the spine.

Lussi M, Fischer G, Bertulli L, Stienen M, Stengel F Acta Neurochir (Wien). 2024; 166(1):391.

PMID: 39356349 DOI: 10.1007/s00701-024-06293-7.


Rehabilitation of Pregnancy and Lactation-Associated Osteoporosis and Vertebral Fractures: A Case Report.

Sahni P, Edeer A, Lindsay R HSS J. 2024; 20(2):298-305.

PMID: 39281988 PMC: 11393619. DOI: 10.1177/15563316231167148.


The C-Brace® microprocessor controlled stance and swing orthosis improves safety, mobility, and quality of life at one year: Interim results from a prospective registry.

Lundstrom R, Klenow T, Morris A, Pobatschnig B, Hibler K, Kannenberg A J Rehabil Assist Technol Eng. 2024; 11:20556683241269539.

PMID: 39132469 PMC: 11316271. DOI: 10.1177/20556683241269539.