» Articles » PMID: 27341340

Noninvasive Evaluation of Bladder Wall Mechanical Properties As a Function of Filling Volume: Potential Application in Bladder Compliance Assessment

Overview
Journal PLoS One
Date 2016 Jun 25
PMID 27341340
Citations 17
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: We propose a novel method to monitor bladder wall mechanical properties as a function of filling volume, with the potential application to bladder compliance assessment. The proposed ultrasound bladder vibrometry (UBV) method uses ultrasound to excite and track Lamb waves on the bladder wall from which its mechanical properties are derived by fitting measurements to an analytical model. Of particular interest is the shear modulus of bladder wall at different volumes, which we hypothesize, is similar to measuring the compliance characteristics of the bladder.

Materials And Methods: Three experimental models were used: 1) an ex vivo porcine model where normal and aberrant (stiffened by formalin) bladders underwent evaluation by UBV; 2) an in vivo study to evaluate the performance of UBV on patients with clinically documented compliant and noncompliant bladders undergoing UDS; and 3) a noninvasive UBV protocol to assess bladder compliance using oral hydration and fractionated voiding on three healthy volunteers.

Results: The ex vivo studies showed a high correlation between the UBV parameters and direct pressure measurement (R2 = 0.84-0.99). A similar correlation was observed for 2 patients with compliant and noncompliant bladders (R2 = 0.89-0.99) undergoing UDS detrusor pressure-volume measurements. The results of UBV on healthy volunteers, performed without catheterization, were comparable to a compliant bladder patient.

Conclusion: The utility of UBV as a method to monitor changes in bladder wall mechanical properties is validated by the high correlation with pressure measurements in ex vivo and in vivo patient studies. High correlation UBV and UDS in vivo studies demonstrated the potential of UBV as a bladder compliance assessment tool. Results of studies on healthy volunteers with normal bladders demonstrated that UBV could be performed noninvasively. Further studies on a larger cohort are needed to fully validate the use of UBV as a clinical tool for bladder compliance assessment.

Citing Articles

Shear wave elastography primer for the abdominal radiologist.

Urban M, Vasconcelos L, Brom K, Dave J, Kijanka P Abdom Radiol (NY). 2025; .

PMID: 39883164 DOI: 10.1007/s00261-025-04806-1.


Structural and mechanical properties of folded protein hydrogels with embedded microbubbles.

Brown C, Hughes M, Mahmoudi N, Brockwell D, Coletta P, Peyman S Biomater Sci. 2023; 11(8):2726-2737.

PMID: 36815670 PMC: 10088474. DOI: 10.1039/d2bm01918c.


Non-Invasive Measurement of the Internal Pressure of a Pressurized Biological Compartment Using Lamb Waves.

Rosen D, Larson N, Alizad A, Fatemi M IEEE Trans Biomed Eng. 2021; 69(6):1860-1869.

PMID: 34807817 PMC: 9713951. DOI: 10.1109/TBME.2021.3129652.


Detrusor overactivity assessment using ultrasound bladder vibrometry.

Rosen D, Husmann D, Mynderse L, Kelly Jr T, Alizad A, Fatemi M Physiol Meas. 2021; 42(10).

PMID: 34598174 PMC: 8609921. DOI: 10.1088/1361-6579/ac2c5c.


Causal contributors to tissue stiffness and clinical relevance in urology.

Martinez-Vidal L, Murdica V, Venegoni C, Pederzoli F, Bandini M, Necchi A Commun Biol. 2021; 4(1):1011.

PMID: 34446834 PMC: 8390675. DOI: 10.1038/s42003-021-02539-7.


References
1.
Mehrmohammadi M, Song P, Meixner D, Fazzio R, Chen S, Greenleaf J . Comb-push ultrasound shear elastography (CUSE) for evaluation of thyroid nodules: preliminary in vivo results. IEEE Trans Med Imaging. 2014; 34(1):97-106. PMC: 4280299. DOI: 10.1109/TMI.2014.2346498. View

2.
Scarpero H, Fiske J, Xue X, Nitti V . American Urological Association Symptom Index for lower urinary tract symptoms in women: correlation with degree of bother and impact on quality of life. Urology. 2003; 61(6):1118-22. DOI: 10.1016/s0090-4295(03)00037-2. View

3.
Hasegawa H, Kanai H . Improving accuracy in estimation of artery-wall displacement by referring to center frequency of RF echo. IEEE Trans Ultrason Ferroelectr Freq Control. 2006; 53(1):52-63. DOI: 10.1109/tuffc.2006.1588391. View

4.
Gennisson J, Deffieux T, Fink M, Tanter M . Ultrasound elastography: principles and techniques. Diagn Interv Imaging. 2013; 94(5):487-95. DOI: 10.1016/j.diii.2013.01.022. View

5.
Montaldo G, Tanter M, Bercoff J, Benech N, Fink M . Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastography. IEEE Trans Ultrason Ferroelectr Freq Control. 2009; 56(3):489-506. DOI: 10.1109/TUFFC.2009.1067. View