» Articles » PMID: 27302414

Feasibility of One-Beat Real-Time Full-Volume Three-Dimensional Echocardiography for Assessing Left Ventricular Volumes and Deformation Parameters

Overview
Specialty Radiology
Date 2016 Jun 16
PMID 27302414
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Real-time three-dimensional echocardiographic (3DE) imaging usually requires multibeat acquisition to maintain high temporal and spatial resolution for full-volume data sets. However, this procedure generates stitch artifacts in patients with irregular heartbeats; thus, one-beat acquisition might be useful. The aim of this study was to compare the efficacy of using new-generation one-beat full-volume acquisition for measuring left ventricular (LV) mechanical parameters with that of four-beat acquisition.

Methods: In protocol 1, 34 patients who had undergone both cardiac magnetic resonance and 3DE imaging on the same day were prospectively enrolled. In protocol 2, 115 patients in sinus rhythm who had undergone 3DE examinations were retrospectively enrolled. LV volume, ejection faction, and global strain were measured using one-beat and four-beat 3DE data sets. In protocol 3, 26 patients with atrial fibrillation who had acquisition of consecutive one-beat full-volume data sets were retrospectively enrolled, and it was determined whether the LV parameters in the index beat were correlated with corresponding average values obtained from multiple one-beat acquisitions.

Results: In protocol 1, the correlations between LV volumes and LV ejection fraction between cardiac magnetic resonance and 3DE imaging with one-beat acquisition were excellent (r = 0.91-0.93). In protocol 2, correlations were also excellent (r = 0.94-0.99), and there were no significant differences in volume rate, LV volumes, LV ejection fraction, and global strain parameters between one-beat and four-beat acquisition data sets. In protocol 3, correlations were excellent (r = 0.94-0.99) between LV parameters from the index beat and corresponding average values.

Conclusions: Three-dimensional echocardiographic full-volume data sets with one-beat acquisition not only maintained volume rate but also provided LV mechanical parameter values similar to those obtained using multibeat acquisition. Using one-beat acquisition for patients with atrial fibrillation expands its clinical applicability.

Citing Articles

Echocardiographic evaluation of left ventricular function using an automated analysis algorithm is feasible for beginners and experts: comparison with invasive and non-invasive methods.

Nicol P, Rank A, Lenz T, Schurmann F, Syryca F, Trenkwalder T J Echocardiogr. 2022; 21(2):65-73.

PMID: 36227498 PMC: 10195710. DOI: 10.1007/s12574-022-00590-9.


Analysis of Cardiac Adverse Reactions Caused by Different Doses of Adriamycin Chemotherapy in Patients with Breast Cancer.

Hu G, Wang D J Healthc Eng. 2022; 2022:1642244.

PMID: 35211251 PMC: 8863445. DOI: 10.1155/2022/1642244.


Usefulness of three-dimensional echocardiography for assessment of left and right ventricular volumes in children, verified by cardiac magnetic resonance. Can we overcome the discrepancy?.

Kaminska H, Malek L, Barczuk-Falecka M, Werner B Arch Med Sci. 2021; 17(1):71-83.

PMID: 33488858 PMC: 7811329. DOI: 10.5114/aoms.2019.84215.


Optimal threshold of three-dimensional echocardiographic fully automated software for quantification of left ventricular volumes and ejection fraction: Comparison with cardiac magnetic resonance disk-area summation method and feature tracking method.

Wu V, Kitano T, Nabeshima Y, Otani K, Chu P, Takeuchi M PLoS One. 2019; 14(1):e0211154.

PMID: 30689657 PMC: 6349335. DOI: 10.1371/journal.pone.0211154.


Realization of fully automated quantification of left ventricular volumes and systolic function using transthoracic 3D echocardiography.

Sun L, Feng H, Ni L, Wang H, Gao D Cardiovasc Ultrasound. 2018; 16(1):2.

PMID: 29357888 PMC: 5778731. DOI: 10.1186/s12947-017-0121-8.