No Effect of Additional Screw Fixation of a Cementless, All-polyethylene Press-fit Socket on Migration, Wear, and Clinical Outcome

Overview
Journal Acta Orthop
Specialty Orthopedics
Date 2016 Jun 15
PMID 27299418
Citations 9
Authors
Affiliations
Soon will be listed here.
Abstract

Background and purpose - Additional screw fixation of the all-polyethylene press-fit RM cup (Mathys) has no additional value for migration, in the first 2 years after surgery. However, the medium-term and long-term effects of screw fixation remain unclear. We therefore evaluated the influence of screw fixation on migration, wear, and clinical outcome at 6.5 years using radiostereometric analysis (RSA). Patients and methods - This study involved prolonged follow-up from a previous randomized controlled trial (RCT). We analyzed RSA radiographs taken at baseline and at 1-, 2-, and 6.5-year follow-up. Cup migration and wear were assessed using model-based RSA software. Wear was calculated as translation of the femoral head model in relation to the cup model. Total translation, rotation, and wear were calculated mathematically from results of the orthogonal components. Results - 27 patients (15 with screw fixation and 12 without) were available for follow-up at 6.5 (5.6-7.2) years. Total translation (0.50 mm vs. 0.56 mm) and rotation (1.01 degrees vs. 1.33 degrees) of the cup was low, and was not significantly different between the 2 groups. Wear increased over time, and was similar between the 2 groups (0.58 mm vs. 0.53 mm). Wear rate (0.08 mm/year vs. 0.09 mm/year) and clinical outcomes were also similar. Interpretation - Our results indicate that additional screw fixation of all-polyethylene press-fit RM cups has no additional value regarding medium-term migration and clinical outcome. The wear rate was low in both groups.

Citing Articles

Mid-term clinical outcomes of the uncemented Robert Mathys pressfit cup.

Ramsodit K, Sierevelt I, Janssen E, Kaarsemaker S, Haverkamp D World J Clin Cases. 2024; 12(19):3684-3691.

PMID: 38994294 PMC: 11235464. DOI: 10.12998/wjcc.v12.i19.3684.


Migration patterns of acetabular cups: a systematic review and meta-analysis of RSA studies.

Cho C, Pijls B, Abrahams J, Roerink A, Katembwe R, Baker A Acta Orthop. 2023; 94:626-634.

PMID: 38157007 PMC: 10757199. DOI: 10.2340/17453674.2023.24580.


Acetabular cup fixation with and without screws following primary total hip arthroplasty: migration evaluated by radiostereometric analysis.

Polus J, Vasarhelyi E, Lanting B, Teeter M Hip Int. 2023; 34(1):42-48.

PMID: 37016808 PMC: 10787387. DOI: 10.1177/11207000231164711.


Revision in Ceramic-on-Ceramic and Ceramic-on-Polyethylene Bearing in Primary Total Hip Arthroplasty with Press-fit Cups: A Systematic Review and Meta-analysis of Different Methodological Study Designs.

van Loon J, de Graeff J, Sierevelt I, Opdam K, Poolman R, Kerkhoffs G Arch Bone Jt Surg. 2022; 10(11):916-936.

PMID: 36561219 PMC: 9749123. DOI: 10.22038/ABJS.2022.59354.2933.


Efficacy and Safety of Acetabular Cup without Screw Fixation in Total Hip Arthroplasty: A Systematic Review and Meta-Analysis.

Miura T, Kijima H, Kimura R, Watanabe J, Okazaki Y, Miyakoshi N Medicina (Kaunas). 2022; 58(8).

PMID: 36013524 PMC: 9413682. DOI: 10.3390/medicina58081058.


References
1.
Heller S, Brosh T, Kosashvili Y, Velkes S, Burg A, Dudkiewicz I . Locking versus standard screw fixation for acetabular cups: is there a difference?. Arch Orthop Trauma Surg. 2013; 133(5):701-5. DOI: 10.1007/s00402-013-1709-6. View

2.
Digas G, Thanner J, Nivbrant B, Rohrl S, Strom H, Karrholm J . Increase in early polyethylene wear after sterilization with ethylene oxide: radiostereometric analyses of 201 total hips. Acta Orthop Scand. 2003; 74(5):531-41. DOI: 10.1080/00016470310017910 . View

3.
Pilliar R, Lee J, Maniatopoulos C . Observations on the effect of movement on bone ingrowth into porous-surfaced implants. Clin Orthop Relat Res. 1986; (208):108-13. View

4.
Thanner J, Karrholm J, Herberts P, Malchau H . Hydroxyapatite and tricalcium phosphate-coated cups with and without screw fixation: a randomized study of 64 hips. J Arthroplasty. 2000; 15(4):405-12. DOI: 10.1054/arth.2000.2963. View

5.
Young A, Sychterz C, Hopper Jr R, Engh C . Effect of acetabular modularity on polyethylene wear and osteolysis in total hip arthroplasty. J Bone Joint Surg Am. 2002; 84(1):58-63. DOI: 10.2106/00004623-200201000-00009. View