» Articles » PMID: 27288090

Multimodality Assessment of Ascending Aortic Diameters: Comparison of Different Measurement Methods

Overview
Specialty Radiology
Date 2016 Jun 12
PMID 27288090
Citations 32
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Transthoracic echocardiography (TTE), multidetector computed tomography (MDCT), and magnetic resonance imaging (MRI) have been widely used to monitor aortic diameters, with no consensus as to the best measurement approach. Thus, the aim of this study was to establish the best measurement methods by two-dimensional (2D) TTE, MDCT, and MRI to achieve comparable aortic diameters.

Methods: One hundred forty patients with severe aortic valvular disease or aortic dilatation were prospectively evaluated using 2D TTE and MDCT (n = 70) or MRI (n = 70). The aorta was measured at three different levels: sinuses of Valsalva, sinotubular junction, and ascending aorta. Three different measurements were made by 2D TTE-inner edge to inner edge, leading edge to leading edge (L-L), and outer edge to outer edge-and then compared with the inner edge-to-inner edge and outer edge-to-outer edge measurements of cusp-to-cusp and cusp-to-commissure diameters by MDCT or MRI. Inter- and intraobserver variability was analyzed.

Results: Aortic diameters by 2D TTE, MDCT, and MRI showed excellent inter- and intraobserver variability using all conventions. Significant underestimation was observed of all aortic diameters assessed by 2D TTE using the inner edge-to-inner edge convention compared with those obtained by MDCT or MRI (P < .0001). However, excellent accuracy was observed by 2D TTE when the L-L convention was used and compared with the internal diameter by MDCT and MRI (mean differences, 0.6 ± 2.6 mm [P = .158] for MDCT and 0.4 ± 3.5 mm [P = .852] for MRI). Cusp-to-cusp diameters were slightly larger than cusp-to-commissure diameters. The diameter by 2D TTE using the L-L convention correlated best with the noncoronary cusp-to-right coronary cusp diameter determined by both MDCT and MRI.

Conclusions: Aortic root and ascending aortic diameters measured by 2D TTE using the L-L convention showed accurate and reproducible values compared with internal diameters assessed by MDCT or MRI. This approach permits a multimodality follow-up of patients with aortic diseases and avoids disparities in measurements obtained by different conventions.

Citing Articles

Aortic growth rates in a Swedish cohort of women with Turner syndrome.

Thunstrom S, Bech-Hanssen O, Krantz E, Bryman I, Landin-Wilhelmsen K Int J Cardiol Congenit Heart Dis. 2024; 15:100489.

PMID: 39713491 PMC: 11657722. DOI: 10.1016/j.ijcchd.2023.100489.


[What is new in the management of peripheral arterial occlusive disease and diseases of the aorta? : Highlights of the ESC guidelines 2024].

Schulze-Bauer H, Staudacher M, Steiner S, Schlager O Herz. 2024; 50(1):25-33.

PMID: 39589444 PMC: 11772412. DOI: 10.1007/s00059-024-05286-7.


The 10 Commandments for State-of-the-Art Imaging of the Proximal Thoracic Aorta.

Boskovski M, Tseng E Innovations (Phila). 2024; 19(6):584-593.

PMID: 39555619 PMC: 11656620. DOI: 10.1177/15569845241297993.


Management of aortic disease in children with FBN1-related Marfan syndrome.

Muino-Mosquera L, Cervi E, De Groote K, Dewals W, Fejzic Z, Kazamia K Eur Heart J. 2024; 45(39):4156-4169.

PMID: 39250726 PMC: 11472455. DOI: 10.1093/eurheartj/ehae526.


Clinical Outcomes in Patients With Bicuspid Aortic Valves and Ascending Aorta ≥50 mm Under Surveillance.

Ye Z, Lane C, Beachey J, Medina-Inojosa J, Galian-Gay L, Dentamaro I JACC Adv. 2024; 2(8):100626.

PMID: 38938356 PMC: 11198710. DOI: 10.1016/j.jacadv.2023.100626.