Correlation Between Central Venous Pressure and Inferior Vena Cava Sonographic Diameter; Determining the Best Anatomic Location

Overview
Journal Emerg (Tehran)
Specialty Emergency Medicine
Date 2016 Jun 9
PMID 27274518
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

Introduction: The correlation of central venous pressure (CVP) with inferior vena cava (IVC) sonographic diameter has been reported in several studies. However, few studies have attempted to find the best anatomic location of measurement. Therefore, the purpose of this study was determining the best anatomic location to find precise correlation between CVP and IVC diameter using transesophageal echocardiography (TEE).

Methods: In the present diagnostic accuracy study, patients in need of central venous catheterization and TEE were enrolled. Maximum diameter of IVC were measured during expiratory phase of respiratory cycle at the level of diaphragm, 2cm above the diaphragm and at the point of entry into the right atrium using SonoSite TEE device. CVP was measured using an electronic transducer connected to the central venous line. The best location for sonography was determined via calculating and comparing area under the receiver operating characteristics (ROC) curve (AUC).

Results: 39 patients were enrolled (53.8% female). Mean CVP was 6.8 ± 1.4 mmHg and 25 (64.1%) patients had normal CVP, while 14 (35.9%) showed elevated CVP (> 6 mmHg). Evaluating AUC showed that IVC diameter (p = 0.01), aorta diameter (p = 0.01) and IVC / aorta ratio (p = 0.004) had acceptable correlation with CVP. Point of entry of IVC into the right atrium with AUC of 0.98 (95% CI: 0.95 - 1.00) was the location of highest correlation with CVP.

Conclusion: Based on the present findings, the IVC sonographic diameter and IVC / aorta ratio had acceptable correlation with CVP at the level of IVC entry into the right atrium.

Citing Articles

Measuring the ratio of femoral vein diameter to femoral artery diameter by ultrasound to estimate volume status.

Ma Z, Gai J, Sun Y, Bai Y, Cai H, Wu L BMC Cardiovasc Disord. 2021; 21(1):506.

PMID: 34670503 PMC: 8527729. DOI: 10.1186/s12872-021-02309-7.


Goal-directed fluid therapy using transoesophageal echocardiographic inferior venacaval index in patients with low left ventricular ejection fraction undergoing major cytoreductive surgery: A clinical trial.

Shah S, Bhargava A, Hariharan U, Jain C, Kulkarni A, Gupta N Saudi J Anaesth. 2020; 14(1):7-14.

PMID: 31998013 PMC: 6970374. DOI: 10.4103/sja.SJA_215_19.


A Comparison between the Bedside Sonographic Measurements of the Inferior Vena Cava Indices and the Central Venous Pressure While Assessing the Decreased Intravascular Volume in Children.

Babaie S, Behzad A, Mohammadpour M, Reisi M Adv Biomed Res. 2018; 7:97.

PMID: 30050885 PMC: 6036785. DOI: 10.4103/abr.abr_213_17.


Establishment of reference values of the caudal vena cava by fast-ultrasonography through different views in healthy dogs.

Darnis E, Boysen S, Merveille A, Desquilbet L, Chalhoub S, Gommeren K J Vet Intern Med. 2018; 32(4):1308-1318.

PMID: 29749656 PMC: 6060313. DOI: 10.1111/jvim.15136.

References
1.
Rivers E, Nguyen B, Havstad S, Ressler J, Muzzin A, Knoblich B . Early goal-directed therapy in the treatment of severe sepsis and septic shock. N Engl J Med. 2002; 345(19):1368-77. DOI: 10.1056/NEJMoa010307. View

2.
Nagdev A, Merchant R, Tirado-Gonzalez A, Sisson C, Murphy M . Emergency department bedside ultrasonographic measurement of the caval index for noninvasive determination of low central venous pressure. Ann Emerg Med. 2009; 55(3):290-5. DOI: 10.1016/j.annemergmed.2009.04.021. View

3.
Riccardi A, Chiarbonello B, Minuto P, Guiddo G, Corti L, Lerza R . Identification of the hydration state in emergency patients: correlation between caval index and BUN/creatinine ratio. Eur Rev Med Pharmacol Sci. 2013; 17(13):1800-3. View

4.
McGee D, Gould M . Preventing complications of central venous catheterization. N Engl J Med. 2003; 348(12):1123-33. DOI: 10.1056/NEJMra011883. View

5.
Ely E, Smith A, Chiles C, Aquino S, Harle T, Evans G . Radiologic determination of intravascular volume status using portable, digital chest radiography: a prospective investigation in 100 patients. Crit Care Med. 2001; 29(8):1502-12. DOI: 10.1097/00003246-200108000-00002. View