» Articles » PMID: 27266995

Accuracy Assessment of Immediate and Delayed Implant Placements Using CAD/CAM Surgical Guides

Overview
Date 2016 Jun 9
PMID 27266995
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

The aim of this study is to assess the accuracy of immediately placed implants using Anatomage Invivo5 computer-assisted design/computer-assisted manufacturing (CAD/CAM) surgical guides and compare the accuracy to delayed implant placement protocol. Patients who had implants placed using Anatomage Invivo5 CAD/CAM surgical guides during the period of 2012-2015 were evaluated retrospectively. Patients who received immediate implant placements and/or delayed implant placements replacing 1-2 teeth were included in this study. Pre- and postsurgical images were superimposed to evaluate deviations at the crest, apex, and angle. A total of 40 implants placed in 29 patients were included in this study. The overall mean deviations measured at the crest, apex, and angle were 0.86 mm, 1.25 mm, and 3.79°, respectively. The means for the immediate group deviations were: crest = 0.85 mm, apex = 1.10, and angle = 3.49°. The means for the delayed group deviations were: crest = 0.88 mm, apex = 1.59, and angle = 4.29°. No statistically significant difference was found at the crest and angle; however, there was a statistically significant difference between the immediate and delayed group at the apex, with the immediate group presenting more accurate placements at the apical point than the delayed group. CAD/CAM surgical guides can be reliable tools to accurately place implants immediately and/or in a delayed fashion. No statistically significant differences were found between the delayed and the immediate group at the crest and angle, however apical position was more accurate in the immediate group.

Citing Articles

Accuracy of implant placement with computer-aided static, dynamic, and robot-assisted surgery: a systematic review and meta-analysis of clinical trials.

Khaohoen A, Powcharoen W, Sornsuwan T, Chaijareenont P, Rungsiyakull C, Rungsiyakull P BMC Oral Health. 2024; 24(1):359.

PMID: 38509530 PMC: 10956322. DOI: 10.1186/s12903-024-04033-y.


Digital implant placement accuracy: a clinical study on a fully-guided flapless single-unit immediate-loading protocol.

Pirooz P, Atri F, Gholami P, Bayat M Maxillofac Plast Reconstr Surg. 2023; 45(1):19.

PMID: 37195351 PMC: 10192503. DOI: 10.1186/s40902-023-00387-5.


Accuracy of keyless vs drill-key implant systems for static computer-assisted implant surgery using two guide-hole designs compared to freehand implant placement: an in vitro study.

Raabe C, Schuetz T, Chappuis V, Yilmaz B, Abou-Ayash S, Couso-Queiruga E Int J Implant Dent. 2023; 9(1):4.

PMID: 36749441 PMC: 9905371. DOI: 10.1186/s40729-023-00470-6.


Application of measurable surgical guides in immediate implant placement and immediate restoration.

Wang Y, Xie C, Zhang Y, Zhang Y, Fang T, Yu H Hua Xi Kou Qiang Yi Xue Za Zhi. 2022; 40(6):731-739.

PMID: 36416329 PMC: 9763961. DOI: 10.7518/hxkq.2022.06.017.


A Retrospective Study on the Transferring Accuracy of a Fully Guided Digital Template in the Anterior Zone.

Huang L, Zhang X, Mo A Materials (Basel). 2021; 14(16).

PMID: 34443154 PMC: 8399113. DOI: 10.3390/ma14164631.