» Articles » PMID: 27231587

Sensitivity of Laser Speckle Contrast Imaging to Flow Perturbations in the Cortex

Overview
Specialty Radiology
Date 2016 May 28
PMID 27231587
Citations 21
Authors
Affiliations
Soon will be listed here.
Abstract

Laser speckle contrast imaging has become a ubiquitous tool for imaging blood flow in a variety of tissues. However, due to its widefield imaging nature, the measured speckle contrast is a depth integrated quantity and interpretation of baseline values and the depth dependent sensitivity of those values to changes in underlying flow has not been thoroughly evaluated. Using dynamic light scattering Monte Carlo simulations, the sensitivity of the autocorrelation function and speckle contrast to flow changes in the cerebral cortex was extensively examined. These simulations demonstrate that the sensitivity of the inverse autocorrelation time, [Formula: see text], varies across the field of view: directly over surface vessels [Formula: see text] is strongly localized to the single vessel, while parenchymal ROIs have a larger sensitivity to flow changes at depths up to 500 μm into the tissue and up to 200 μm lateral to the ROI. It is also shown that utilizing the commonly used models the relate [Formula: see text] to flow resulted in nearly the same sensitivity to the underlying flow, but fail to accurately relate speckle contrast values to absolute [Formula: see text].

Citing Articles

Improvements and validation of spatiotemporal speckle correlation model for rolling shutter speckle imaging.

Yi C, Byun S, Lee Y, Ah Lee S Biomed Opt Express. 2024; 15(2):1253-1267.

PMID: 38404314 PMC: 10890878. DOI: 10.1364/BOE.514497.


Dynamic light scattering and laser speckle contrast imaging of the brain: theory of the spatial and temporal statistics of speckle pattern evolution.

Liu B, Postnov D, Boas D, Cheng X Biomed Opt Express. 2024; 15(2):579-593.

PMID: 38404305 PMC: 10890898. DOI: 10.1364/BOE.510333.


Wide dynamic range measurement of blood flow using laser speckle contrast imaging.

Liu H, Yuan Y, Han L, Bi Y, Yu W, Yu Y J Biomed Opt. 2024; 29(1):016009.

PMID: 38283936 PMC: 10821768. DOI: 10.1117/1.JBO.29.1.016009.


Choosing a polarisation configuration for dynamic light scattering and laser speckle contrast imaging.

Akther S, Mikkelsen M, Postnov D Biomed Opt Express. 2024; 15(1):336-345.

PMID: 38223196 PMC: 10783896. DOI: 10.1364/BOE.507367.


Quasi-analytic solution for real-time multi-exposure speckle imaging of tissue perfusion.

Rivera D, Schaffer C Biomed Opt Express. 2023; 14(8):3950-3967.

PMID: 37799691 PMC: 10549738. DOI: 10.1364/BOE.493821.


References
1.
Lorthois S, Cassot F, Lauwers F . Simulation study of brain blood flow regulation by intra-cortical arterioles in an anatomically accurate large human vascular network. Part II: flow variations induced by global or localized modifications of arteriolar diameters. Neuroimage. 2010; 54(4):2840-53. DOI: 10.1016/j.neuroimage.2010.10.040. View

2.
Carp S, Roche-Labarbe N, Franceschini M, Srinivasan V, Sakadzic S, Boas D . Due to intravascular multiple sequential scattering, Diffuse Correlation Spectroscopy of tissue primarily measures relative red blood cell motion within vessels. Biomed Opt Express. 2011; 2(7):2047-54. PMC: 3130588. DOI: 10.1364/BOE.2.002047. View

3.
Duncan D, Kirkpatrick S, Wang R . Statistics of local speckle contrast. J Opt Soc Am A Opt Image Sci Vis. 2007; 25(1):9-15. DOI: 10.1364/josaa.25.000009. View

4.
Richards L, Towle E, Fox Jr D, Dunn A . Intraoperative laser speckle contrast imaging with retrospective motion correction for quantitative assessment of cerebral blood flow. Neurophotonics. 2015; 1(1):015006. PMC: 4479045. DOI: 10.1117/1.NPh.1.1.015006. View

5.
Armitage G, Todd K, Shuaib A, Winship I . Laser speckle contrast imaging of collateral blood flow during acute ischemic stroke. J Cereb Blood Flow Metab. 2010; 30(8):1432-6. PMC: 2949243. DOI: 10.1038/jcbfm.2010.73. View