» Articles » PMID: 27225405

Evaluation of the Vitek MS Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry System for Identification of Clinically Relevant Filamentous Fungi

Overview
Specialty Microbiology
Date 2016 May 27
PMID 27225405
Citations 28
Authors
Affiliations
Soon will be listed here.
Abstract

Invasive fungal infections have a high rate of morbidity and mortality, and accurate identification is necessary to guide appropriate antifungal therapy. With the increasing incidence of invasive disease attributed to filamentous fungi, rapid and accurate species-level identification of these pathogens is necessary. Traditional methods for identification of filamentous fungi can be slow and may lack resolution. Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has emerged as a rapid and accurate method for identification of bacteria and yeasts, but a paucity of data exists on the performance characteristics of this method for identification of filamentous fungi. The objective of our study was to evaluate the accuracy of the Vitek MS for mold identification. A total of 319 mold isolates representing 43 genera recovered from clinical specimens were evaluated. Of these isolates, 213 (66.8%) were correctly identified using the Vitek MS Knowledge Base, version 3.0 database. When a modified SARAMIS (Spectral Archive and Microbial Identification System) database was used to augment the version 3.0 Knowledge Base, 245 (76.8%) isolates were correctly identified. Unidentified isolates were subcultured for repeat testing; 71/319 (22.3%) remained unidentified. Of the unidentified isolates, 69 were not in the database. Only 3 (0.9%) isolates were misidentified by MALDI-TOF MS (including Aspergillus amoenus [n = 2] and Aspergillus calidoustus [n = 1]) although 10 (3.1%) of the original phenotypic identifications were not correct. In addition, this methodology was able to accurately identify 133/144 (93.6%) Aspergillus sp. isolates to the species level. MALDI-TOF MS has the potential to expedite mold identification, and misidentifications are rare.

Citing Articles

Identification of Challenging Dermatophyte Species Using Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry.

Tsai T, Fan Y, Lu J, Chien C, Wang H, Sun P J Fungi (Basel). 2025; 11(2).

PMID: 39997401 PMC: 11856511. DOI: 10.3390/jof11020107.


Evaluation of two MALDI-TOF MS systems and extraction methods for identification of filamentous fungi recovered from clinical specimens.

Ransom E, Wallace M, Wiederhold N, Canete-Gibas C, Burnham C J Clin Microbiol. 2025; 63(2):e0154824.

PMID: 39807897 PMC: 11837564. DOI: 10.1128/jcm.01548-24.


Performance of the VITEK® MS system for the identification of filamentous fungi in a microbiological laboratory in Chile.

Porte L, Cruz R, Perez I, Varela C, Diaz C, Garcia P PLoS One. 2024; 19(12):e0315690.

PMID: 39715188 PMC: 11666008. DOI: 10.1371/journal.pone.0315690.


MALDI-TOF Mass Spectrometry in Clinical Analysis and Research.

Li D, Yi J, Han G, Qiao L ACS Meas Sci Au. 2023; 2(5):385-404.

PMID: 36785658 PMC: 9885950. DOI: 10.1021/acsmeasuresciau.2c00019.


Mass spectrometry in research laboratories and clinical diagnostic: a new era in medical mycology.

Kamali Sarvestani H, Ramandi A, Getso M, Razavyoon T, Javidnia J, Banay Golrizi M Braz J Microbiol. 2022; 53(2):689-707.

PMID: 35344203 PMC: 9151960. DOI: 10.1007/s42770-022-00715-3.


References
1.
Patel R . MALDI-TOF MS for the diagnosis of infectious diseases. Clin Chem. 2014; 61(1):100-11. DOI: 10.1373/clinchem.2014.221770. View

2.
Garner O, Mochon A, Branda J, Burnham C, Bythrow M, Ferraro M . Multi-centre evaluation of mass spectrometric identification of anaerobic bacteria using the VITEK® MS system. Clin Microbiol Infect. 2013; 20(4):335-9. DOI: 10.1111/1469-0691.12317. View

3.
Wilen C, McMullen A, Burnham C . Comparison of Sample Preparation Methods, Instrumentation Platforms, and Contemporary Commercial Databases for Identification of Clinically Relevant Mycobacteria by Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry. J Clin Microbiol. 2015; 53(7):2308-15. PMC: 4473241. DOI: 10.1128/JCM.00567-15. View

4.
Panda A, Ghosh A, Mirdha B, Xess I, Paul S, Samantaray J . MALDI-TOF mass spectrometry for rapid identification of clinical fungal isolates based on ribosomal protein biomarkers. J Microbiol Methods. 2014; 109:93-105. DOI: 10.1016/j.mimet.2014.12.014. View

5.
Rychert J, Burnham C, Bythrow M, Garner O, Ginocchio C, Jennemann R . Multicenter evaluation of the Vitek MS matrix-assisted laser desorption ionization-time of flight mass spectrometry system for identification of Gram-positive aerobic bacteria. J Clin Microbiol. 2013; 51(7):2225-31. PMC: 3697712. DOI: 10.1128/JCM.00682-13. View