» Articles » PMID: 27198891

Clinical, Angiographic and Procedural Characteristics of Longitudinal Stent Deformation

Overview
Publisher Springer
Specialty Radiology
Date 2016 May 21
PMID 27198891
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

Recently, longitudinal stent deformation (LSD) has been reported increasingly. Even though the reported cases included almost all stent designs, most cases were seen in the Element™ stent design (Boston Scientific, Natick, MA, USA). It is considered that stent design, lesion and procedural characteristics play a role in the etiology of LSD. Yet, the effect of LSD on long-term clinical outcomes has not been studied well. Element stents implanted between January 2013 and April 2015 in our hospital were examined retrospectively. Patients were grouped into two according to the presence of LSD, and their clinical, lesion and procedural characteristics were studied. Twenty-four LSD's were detected in 1812 Element stents deployed in 1314 patients (1.83 % of PCI cases and 1.32 % of all Element stents). LMCA lesions (16.7 % vs 1.6 %, p < 0.001), complex lesions (75 % vs 35.1 %, p < 0.001), bifurcation lesions (37.5 % vs 18.3 %, p = 0.017), ostial lesions (33.3 % vs 12.8 %, p = 0.003), using of extra-support guiding catheter (54.2 % vs 22.3 %, p < 0.001) and extra-support guidewire (37.5 % vs 16.2 %, p = 0.005) were found to be more frequent in cases with LSD than in cases without it. In addition, the number of stents, stent inflation pressure and the use of post-dilatation were significantly different between the two groups. Two patients had an adverse event during the follow-up period. LSD is a rarely encountered complication, and is more common in complex lesions such as ostial, bifurcation and LMCA lesions. The use of extra-support guiding catheter, extra-support guidewires and low stent inflation pressure increases the occurrence of LSD. Nevertheless, with increased awareness of LSD and proper treatment, unwanted long-term outcomes can be successfully prevented.

Citing Articles

Longitudinal Stent Deformation in Undeployed Stents: A Case Series.

Otaal P, Bootla D J Tehran Heart Cent. 2022; 16(3):123-128.

PMID: 35633828 PMC: 9108479. DOI: 10.18502/jthc.v16i3.8190.


In-stent restenosis and longitudinal stent deformation: a case report.

Si D, Tong Y, Yu B, He Y, Liu G BMC Cardiovasc Disord. 2020; 20(1):24.

PMID: 31952504 PMC: 6969443. DOI: 10.1186/s12872-020-01335-1.


Thin and crush: The new mantra in left main stenting?.

Rigatelli G, Zuin M, Dash D World J Cardiol. 2018; 10(11):191-195.

PMID: 30510635 PMC: 6259027. DOI: 10.4330/wjc.v10.i11.191.


A catastrophic nightmare of the interventional cardiologist: Iatrogenic left main artery dissection and longitudinal stent deformation.

Yildirim O, Gul M, Inci S, Aktas H, Dogan P, Bozkir A Intractable Rare Dis Res. 2018; 7(3):209-212.

PMID: 30181944 PMC: 6119667. DOI: 10.5582/irdr.2018.01081.


The potential hazard of a non-slip element balloon causing distal longitudinal stent deformation: the first clinical experience and in vitro assessment.

Shibutani H, Akita Y, Oishi Y, Sueyoshi H, Mukai Y, Yutaka K Cardiol J. 2018; 26(6):645-652.

PMID: 29924377 PMC: 8083032. DOI: 10.5603/CJ.a2018.0065.


References
1.
Stone G, Teirstein P, Meredith I, Farah B, Dubois C, Feldman R . A prospective, randomized evaluation of a novel everolimus-eluting coronary stent: the PLATINUM (a Prospective, Randomized, Multicenter Trial to Assess an Everolimus-Eluting Coronary Stent System [PROMUS Element] for the Treatment of Up to Two de.... J Am Coll Cardiol. 2011; 57(16):1700-8. DOI: 10.1016/j.jacc.2011.02.016. View

2.
Serruys P, Silber S, Garg S, van Geuns R, Richardt G, Buszman P . Comparison of zotarolimus-eluting and everolimus-eluting coronary stents. N Engl J Med. 2010; 363(2):136-46. DOI: 10.1056/NEJMoa1004130. View

3.
Ormiston J, Webber B, Webster M . Stent longitudinal integrity bench insights into a clinical problem. JACC Cardiovasc Interv. 2011; 4(12):1310-7. DOI: 10.1016/j.jcin.2011.11.002. View

4.
Abdel-Wahab M, Sulimov D, Kassner G, Geist V, Toelg R, Richardt G . Longitudinal deformation of contemporary coronary stents: an integrated analysis of clinical experience and observations from the bench. J Interv Cardiol. 2012; 25(6):576-85. DOI: 10.1111/j.1540-8183.2012.00765.x. View

5.
Arnous S, Shakhshir N, Wiper A, Ordoubadi F, Williams P, Clarke B . Incidence and mechanisms of longitudinal stent deformation associated with Biomatrix, Resolute, Element, and Xience stents: Angiographic and case-by-case review of 1,800 PCIs. Catheter Cardiovasc Interv. 2014; 86(6):1002-11. DOI: 10.1002/ccd.25790. View