Potentially-implantable, Amperometric Glucose Sensors with Mediated Electron Transfer: Improving the Operating Stability

Overview
Journal Biosensors
Date 1989 Jan 1
PMID 2719726
Citations 11
Authors
Affiliations
Soon will be listed here.
Abstract

The major problems with existing amperometric enzyme electrodes for glucose sensing are oxygen sensitivity and output drift. The recently described miniature glucose sensors using immobilised ferrocene (dicyclopentadienyl iron) to mediate electron transfer from glucose oxidase to a base electrode are oxygen-independent but are often unstable. In this study, we test the hypothesis that the stability of ferrocene-based sensors can be markedly improved by better retention of the enzyme at the electrode. Sensors with graphite foil as the base electrode, dimethylferrocene as the mediator and carbodiimide/glutaraldehyde for enzyme immobilisation lost most of their activity when calibration curves were compared before and after 18 h operation in vitro at 37 degrees C (mean current decrease at 20 mmol/litre glucose was 91%). This sensor type with a covering cellulose membrane also lost activity (mean current decrease of 40% after 18 h). Electrodes in which the base sensor was platinum and the enzyme was covalently attached to agarose lost no activity when operated either at 700 mV without mediator (as a hydrogen peroxide detector) or at 160 mV with mediator. We conclude that both ferrocene-mediated and hydrogen peroxide-detecting amperometric glucose sensors with a high density of covalently-linked enzyme have an operating stability in vitro which may render them suitable for clinical use as, for example, an overnight hypoglycaemia alarm.

Citing Articles

Short-term outcomes and healthcare resource utilization following incisional hernia repair with synthetic mesh in patients with Crohn's disease.

Perlmutter B, Alkhatib H, Lightner A, Fafaj A, Zolin S, Petro C Hernia. 2021; 25(6):1557-1564.

PMID: 34342743 DOI: 10.1007/s10029-021-02476-8.


Pre- and postsurgical imaging findings of abdominal wall hernias based on the European Hernia Society (EHS) classification.

Aluja-Jaramillo F, Cifuentes-Sandoval S, Gutierrez F, Bhalla S, Menias C Abdom Radiol (NY). 2021; 46(11):5055-5071.

PMID: 34292364 DOI: 10.1007/s00261-021-03211-8.


Totally endoscopic sublay (TES) repair for lateral abdominal wall hernias: technique and first results.

Li B, Qin C, Yu J, Gong D, Nie X, Li G Hernia. 2021; 25(2):523-533.

PMID: 33599899 DOI: 10.1007/s10029-021-02374-z.


Flexible Electronics for Monitoring Electrophysiology and Metabolite Signals.

Choi H, Lee J, Lee T, Lee S, Choi J Front Chem. 2020; 8:547591.

PMID: 33330353 PMC: 7710703. DOI: 10.3389/fchem.2020.547591.


Prehabilitation of complex ventral hernia patients with Botulinum: a systematic review of the quantifiable effects of Botulinum.

Wegdam J, de Vries Reilingh T, Bouvy N, Nienhuijs S Hernia. 2020; 25(6):1427-1442.

PMID: 33215244 DOI: 10.1007/s10029-020-02333-0.