» Articles » PMID: 271201

Maximal Stress Test Performance While Wearing a Self-contained Breathing Apparatus

Overview
Journal J Occup Med
Date 1977 Dec 1
PMID 271201
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Fifteen adult male volunteers (mean age = 31.0 years; eight non-smokers and seven smokers) carried out a Bruce protocol maximal treadmill stress test under four separate conditions. These four conditions were (1) without Scott Air Pak (SAP) respirator; (2) with SAP respirator apparatus but not wearing face mask; (3) with SAP apparatus, wearing face mask in "demand" breathing mode; and (4) with SAP respirator apparatus, wearing face mask in "pressure-demand" breathing mode. The data indicate that the overriding factor in the approximately 20% decrement in work performance during conditions 2, 3, and 4 was related to the weight of the SAP respirator (15.8 kg), P less than 0.05. Only during condition 3 did eight of 15 subjects report lack of air as one reason for termination. Conditions 3 and 4 resulted in a significant decrease in TFore (2.5 degrees C) and was primarily related to the decreased Tinsp which reached a maximum decrement of 9.7 degrees C. Under all conditions the smokers' work time was significantly less than nonsmokers, P less than 0.05.

Citing Articles

The Effect of Inspiratory Resistance on Exercise Performance and Perception in Moderate Normobaric Hypoxia.

Seo Y, Vaughan J, Quinn T, Followay B, Roberge R, Glickman E High Alt Med Biol. 2017; 18(4):417-424.

PMID: 29112466 PMC: 10542912. DOI: 10.1089/ham.2017.0103.


The effects of thoracic load carriage on maximal ambulatory work tolerance and acceptable work durations.

Peoples G, Lee D, Notley S, Taylor N Eur J Appl Physiol. 2016; 116(3):635-46.

PMID: 26739503 DOI: 10.1007/s00421-015-3323-5.


The impact of firefighter personal protective equipment and treadmill protocol on maximal oxygen uptake.

Lee J, Bakri I, Kim J, Son S, Tochihara Y J Occup Environ Hyg. 2013; 10(7):397-407.

PMID: 23668854 PMC: 4620539. DOI: 10.1080/15459624.2013.792681.


Maximal physical work performance with European standard based fire-protective clothing system and equipment in relation to individual characteristics.

Louhevaara V, Ilmarinen R, Griefahn B, Kunemund C, Makinen H Eur J Appl Physiol Occup Physiol. 1995; 71(2-3):223-9.

PMID: 7588692 DOI: 10.1007/BF00854982.


Cardiorespiratory effects of respiratory protective devices during exercise in well-trained men.

Louhevaara V, Tuomi T, Korhonen O, Jaakkola J Eur J Appl Physiol Occup Physiol. 1984; 52(3):340-5.

PMID: 6539691 DOI: 10.1007/BF01015224.