Left Mainstem Bronchus Rupture Due to a Left-sided Double Lumen Tube
Overview
Authors
Affiliations
Double lumen tubes (DLT) are a cornerstone in thoracic anaesthesia to achieve onelung ventilation. Due to the shape and size of these devices, airway injuries might occur. The reported incidence of tracheobronchial ruptures caused by a DLT is very low (0.005% for single-lumen tubes and 0.05% for double-lumen intubations), but the outcome can be life-threatening (1, 2). In the past, treatment of tracheobronchial ruptures was performed surgically, nowadays conservative treatment can be considered (3, 4). Here, we report a case of tracheobronchial rupture during oesophageal surgery.
Luo K, Chen K, Li Y, Ji Y J Cardiothorac Surg. 2024; 19(1):361.
PMID: 38915035 PMC: 11194903. DOI: 10.1186/s13019-024-02840-6.
Li X, He X, Wan L, Liu C, Cui Y Medicine (Baltimore). 2020; 99(16):e19704.
PMID: 32311952 PMC: 7440194. DOI: 10.1097/MD.0000000000019704.
Asian perspectives in thoracic surgery: clinical innovation in Taiwan.
Liu C, Lin C, Liu C J Thorac Dis. 2016; 8(Suppl 8):S606-12.
PMID: 27651935 PMC: 5009066. DOI: 10.21037/jtd.2016.08.64.