» Articles » PMID: 27054864

Influence of Working Length and Foraminal Enlargement on Foramen Morphology and Sealing Ability

Overview
Specialty Dentistry
Date 2016 Apr 8
PMID 27054864
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

Aim: The present study evaluated the influence of the working length and foraminal enlargement on the sealing ability and anatomy of the apical region of the root.

Materials And Methods: Fifty-five roots were divided into three groups: G1, instrumentation 1 mm short of the major foramen; G2, instrumentation in the limit of the apical foramen; and G3, instrumentation 1 mm beyond the foramen. All groups were prepared using nickel-titanium rotary files and obturated with AH Plus and Gutta-percha. Photomicrographs were taken using a scanning electron microscopy (SEM) before instrumentation, after instrumentation with each file, and after root canal filling. Moreover, bacterial microleakage with Enterococcus faecalis was performed.

Results: The results were analyzed using Mann-Whitney, Friedman, Kruskal-Wallis and Kaplan-Meier tests at a significance level of 5%. The cemental canal was uninstrumented in G1. No statistical differences regarding foramen deviation was observed when compared G2 and G3 (P > 0.05). SEM analysis showed that G2 and G3 resulted in good apical foramen obturation. Microleakage showed no statistically significant differences between all of the groups tested.

Conclusions: Under the conditions of this study, it can be concluded that foramen enlargement resulted in more apical deviation; however, no differences in bacterial microleakage was observed among the experimental groups.

Citing Articles

ProDesign Logic Files Effect on Apical Foramen Wear and Shape Transformation After Foraminal Enlargement.

Castillo Marin M, Abu Hasna A, Frozoni M, Diamantino M, Rocha C, Valera M Dent J (Basel). 2024; 12(10).

PMID: 39452458 PMC: 11506177. DOI: 10.3390/dj12100330.


Influence of working length and anatomical complexities on the apical root canal filling: a nano-CT study.

Lobo N, Jacobs R, Vasconcelos K, Wanderley V, Santos B, Marciano M Braz Dent J. 2022; 33(3):1-7.

PMID: 35766712 PMC: 9645203. DOI: 10.1590/0103-6440202204576.


Passive Ultrasonic Irrigation Efficacy in the Vapor Lock Removal: Systematic Review and Meta-Analysis.

Dioguardi M, Gioia G, Illuzzi G, Ciavarella D, Laneve E, Troiano G ScientificWorldJournal. 2019; 2019:6765349.

PMID: 30992694 PMC: 6434262. DOI: 10.1155/2019/6765349.


Foramen Changes following Over Instrumentation of Curved Canals with Three Engine-Driven Instruments: An Study.

Yammine S, Jabbour E, Nahas P, Majzoub Z Iran Endod J. 2017; 12(4):454-461.

PMID: 29225641 PMC: 5722120. DOI: 10.22037/iej.v12i4.16268.