Low Mechanical Index Contrast Mode Versus High Mechanical Index Contrast Mode: Which is a More Sensitive Method for Detecting Sonazoid Microbubbles in the Liver of Normal Subjects?

Overview
Specialty Radiology
Date 2016 Apr 2
PMID 27033867
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: Using the low mechanical index (MI) contrast mode and the high MI contrast mode of contrast-enhanced ultrasonography, we evaluated which method is more sensitive for detecting Sonazoid microbubbles in the liver of normal subjects.

Methods: Thirteen normal subjects received an intravenous bolus injection of 0.2 mL of Sonazoid. We defined the intensity difference as the intensity post-injection minus the intensity pre-injection. We evaluated the intensity difference at the portal vein using both the low MI (0.21-0.23) and the high MI (0.7-1.2) at 1 min, at every 10 min between 10 to 60 min, and at every 30 min between 60 to 300 min post-injection. The intensity difference at the liver parenchyma was also evaluated at eight points (1, 10, 30, 60, 120, 180, 240, and 300 min) using the low MI and at three points (1, 10, and 300 min) using the high MI.

Results: The intensity differences at the portal vein measured using high MI were significantly higher than those measured using the low MI at each point between 1 and 240 min (P < 0.01) and at 270 min post-injection (P < 0.05). The intensity differences at the liver parenchyma measured using the high MI were also significantly higher than those measured using the low MI at each time point (P < 0.01).

Conclusion: Compared with the low MI, the high MI is more sensitive for detecting Sonazoid microbubbles in the liver of normal subjects.

Citing Articles

The Role of Molecular Imaging in Personalized Medicine.

Salih S, Elliyanti A, Alkatheeri A, AlYafei F, Almarri B, Khan H J Pers Med. 2023; 13(2).

PMID: 36836603 PMC: 9959741. DOI: 10.3390/jpm13020369.


The AFSUMB Consensus Statements and Recommendations for the Clinical Practice of Contrast-Enhanced Ultrasound using Sonazoid.

Lee J, Minami Y, Choi B, Lee W, Chou Y, Jeong W J Med Ultrasound. 2020; 28(2):59-82.

PMID: 32874864 PMC: 7446696. DOI: 10.4103/JMU.JMU_124_19.


The AFSUMB Consensus Statements and Recommendations for the Clinical Practice of Contrast-Enhanced Ultrasound using Sonazoid.

Lee J, Minami Y, Choi B, Lee W, Chou Y, Jeong W Ultrasonography. 2020; 39(3):191-220.

PMID: 32447876 PMC: 7315291. DOI: 10.14366/usg.20057.


Application of new ultrasound techniques for focal liver lesions.

Wang F, Numata K, Nihonmatsu H, Okada M, Maeda S J Med Ultrason (2001). 2020; 47(2):215-237.

PMID: 31950396 DOI: 10.1007/s10396-019-01001-w.


Safety of Perfluorobutane (Sonazoid) in Characterizing Focal Liver Lesions.

Chou Y, Liang J, Wang S, Hsu S, Hu J, Yang S J Med Ultrasound. 2019; 27(2):81-85.

PMID: 31316217 PMC: 6607878. DOI: 10.4103/JMU.JMU_44_19.

References
1.
Numata K, Tanaka K, Kiba T, Mitsui K, Saito S, Sekihara H . Hemodynamic changes in hepatic artery after glucose ingestion in healthy subjects and patients with cirrhosis. J Clin Ultrasound. 1998; 26(3):137-42. DOI: 10.1002/(sici)1097-0096(199803/04)26:3<137::aid-jcu5>3.0.co;2-n. View

2.
Numata K, Luo W, Morimoto M, Kondo M, Kunishi Y, Sasaki T . Contrast enhanced ultrasound of hepatocellular carcinoma. World J Radiol. 2010; 2(2):68-82. PMC: 2998925. DOI: 10.4329/wjr.v2.i2.68. View

3.
Takizawa K, Numata K, Morimoto M, Kondo M, Nozaki A, Moriya S . Use of contrast-enhanced ultrasonography with a perflubutane-based contrast agent performed one day after transarterial chemoembolization for the early assessment of residual viable hepatocellular carcinoma. Eur J Radiol. 2013; 82(9):1471-80. DOI: 10.1016/j.ejrad.2013.04.045. View

4.
Moriyasu F, Itoh K . Efficacy of perflubutane microbubble-enhanced ultrasound in the characterization and detection of focal liver lesions: phase 3 multicenter clinical trial. AJR Am J Roentgenol. 2009; 193(1):86-95. DOI: 10.2214/AJR.08.1618. View

5.
Alzaraa A, Gravante G, Chung W, Al-Leswas D, Morgan B, Dennison A . Contrast-enhanced ultrasound in the preoperative, intraoperative and postoperative assessment of liver lesions. Hepatol Res. 2013; 43(8):809-19. DOI: 10.1111/hepr.12044. View