» Articles » PMID: 27014356

Complications of Cardiac Catheterization in Structural Heart Disease

Overview
Journal Korean Circ J
Date 2016 Mar 26
PMID 27014356
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

Background And Objectives: Cardiac catheterization is used to diagnose structural heart disease (SHD) and perform transcatheter treatment. This study aimed to evaluate complications of cardiac catheterization and the associated risk factors in a tertiary center over 10 years.

Subjects And Methods: Total 2071 cardiac catheterizations performed at the Seoul National University Children's Hospital from January 2004 to December 2013 were included in this retrospective study.

Results: The overall complication, severe complication, and mortality rates were 16.2%, 1.15%, and 0.19%, respectively. The factors that significantly increased the risk of overall and severe complications were anticoagulant use before procedure (odds ratio [OR] 1.83, p=0.012 and OR 6.45, p<0.001, respectively), prothrombin time (OR 2.30, p<0.001 and OR 5.99, p<0.001, respectively), general anesthesia use during procedure (OR 1.84, p=0.014 and OR 5.31, p=0.015, respectively), and total procedure time (OR 1.01, p<0.001 and OR 1.02, p<0.001, respectively). Low body weight (OR 0.99, p=0.003), severe SHD (OR 1.37, p=0.012), repetitive procedures (OR 1.7, p=0.009), and total fluoroscopy time (OR 1.01, p=0.005) significantly increased the overall complication risk. High activated partial thromboplastin time (OR 1.04, p=0.001), intensive care unit admission state (OR 14.03, p<0.001), and concomitant electrophysiological study during procedure (OR 3.41, p=0.016) significantly increased severe complication risk.

Conclusion: Currently, the use of cardiac catheterization in SHD is increasing and becoming more complex; this could cause complications despite the preventive efforts. Careful patient selection for therapeutic catheterization and improved technique and management during the peri-procedural period are required to reduce complications.

Citing Articles

Congenital heart disease cardiac catheterization at Uganda Heart Institute, a 12-year retrospective study of immediate outcomes.

Mbabazi N, Aliku T, Namuyonga J, Tumwebaze H, Ndagire E, Obongonyinge B BMC Cardiovasc Disord. 2024; 24(1):463.

PMID: 39210275 PMC: 11360719. DOI: 10.1186/s12872-024-04085-6.


Vascular Reconstruction in a Neonate after Iatrogenic Injury during Cardiac Catheterization.

Amaro E, Pophal S, Zoldos J Plast Reconstr Surg Glob Open. 2018; 5(12):e1600.

PMID: 29632779 PMC: 5889463. DOI: 10.1097/GOX.0000000000001600.


Outcomes Associated with the Off-label Use of Medical Devices in Congenital Heart Disease at a Single Institute.

Kong Y, Song J, Huh J, Kang I Korean Circ J. 2017; 47(4):509-515.

PMID: 28765743 PMC: 5537153. DOI: 10.4070/kcj.2016.0311.

References
1.
Mori Y, Nakazawa M, Yagihara T . Complications of pediatric cardiac catheterization and system of catheterization laboratories minimizing complications--a Japanese multicenter survey. J Cardiol. 2010; 56(2):183-8. DOI: 10.1016/j.jjcc.2010.05.001. View

2.
de Bono D . Complications of diagnostic cardiac catheterisation: results from 34,041 patients in the United Kingdom confidential enquiry into cardiac catheter complications. The Joint Audit Committee of the British Cardiac Society and Royal College of.... Br Heart J. 1993; 70(3):297-300. PMC: 1025320. DOI: 10.1136/hrt.70.3.297. View

3.
Vitiello R, McCrindle B, Nykanen D, Freedom R, Benson L . Complications associated with pediatric cardiac catheterization. J Am Coll Cardiol. 1998; 32(5):1433-40. DOI: 10.1016/s0735-1097(98)00396-9. View

4.
Brotschi B, Hug M, Kretschmar O, Rizzi M, Albisetti M . Incidence and predictors of cardiac catheterisation-related arterial thrombosis in children. Heart. 2015; 101(12):948-53. DOI: 10.1136/heartjnl-2014-306713. View

5.
Yetman A, Nykanen D, McCrindle B, Sunnegardh J, Adatia I, Freedom R . Balloon angioplasty of recurrent coarctation: a 12-year review. J Am Coll Cardiol. 1997; 30(3):811-6. DOI: 10.1016/s0735-1097(97)00228-3. View