» Articles » PMID: 27014351

Right Cardiac Catheterization Using the Antecubital Fossa Vein in Korean Patients

Overview
Journal Korean Circ J
Date 2016 Mar 26
PMID 27014351
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

Background And Objectives: Right heart catheterization is traditionally performed using a femoral vein approach that involves admission, bed rest, and risks of bleeding and hematoma. Recent studies have confirmed safety of the use of forearm vein for right cardiac catheterization. In the present study, we evaluated the feasibility of right cardiac catheterization via the antecubital fossa vein in Korean patients.

Subjects And Methods: The medical records of all patients who underwent right heart catheterization at our hospital between January 2003 and December 2014 were reviewed retrospectively. Right cardiac catheterizations via the antecubital fossa vein and the femoral vein were compared in terms of demographic data (age, sex, weight, height, and body mass index), indications for right cardiac catheterization, and procedural and outcome data (initial success rate, procedure time, compression to ambulation time, and complications).

Results: We reviewed 132 cases (antecubital fossa vein approach, n=37; femoral vein approach, n=95). The demographic data, initial success rate (100% vs. 100%) and procedure time (21.6±16.8 min vs. 25.6±12.6 min, p=0.14) were similar in both groups. The antecubital fossa vein group had a shorter mean compression to ambulation time than the femoral vein group (0.0 min vs. 201.2±48.1 min, p<0.01). No complications were observed in either group.

Conclusion: Our study indicated the ease of performance of right cardiac catheterization via the antecubital fossa vein. Thus, the antecubital fossa vein can be an alternative access site for right cardiac catheterization in Korean patients.

Citing Articles

Ultrasound-guided antecubital vein approach for right heart catheterisation in a Brazilian tertiary centre.

Valle F, Wainstein R, Matte B, Cadaval Goncalves S, Bergoli L, Krepsky A Open Heart. 2020; 7(1):e001181.

PMID: 32153790 PMC: 7046939. DOI: 10.1136/openhrt-2019-001181.


The best vein to be accessed based on descriptive study of dorsal metacarpal vein.

Salameh M, Shatarat A, Badran D, Abu-Abeeleh M, Massad I, Bani-Hani A Anat Cell Biol. 2020; 52(4):390-396.

PMID: 31949977 PMC: 6952693. DOI: 10.5115/acb.19.142.


Right heart catheterization procedures in patients with suspicion of pulmonary hypertension - experiences of a tertiary center.

Grymuza M, Malaczynska-Rajpold K, Jankiewicz S, Siniawski A, Grygier M, Mitkowski P Postepy Kardiol Interwencyjnej. 2018; 13(4):295-301.

PMID: 29362571 PMC: 5770859. DOI: 10.5114/aic.2017.71610.

References
1.
Kiemeneij F, Laarman G, Odekerken D, Slagboom T, van der Wieken R . A randomized comparison of percutaneous transluminal coronary angioplasty by the radial, brachial and femoral approaches: the access study. J Am Coll Cardiol. 1997; 29(6):1269-75. DOI: 10.1016/s0735-1097(97)00064-8. View

2.
Lo T, Buch A, Hall I, Hildick-Smith D, Nolan J . Percutaneous left and right heart catheterization in fully anticoagulated patients utilizing the radial artery and forearm vein: a two-center experience. J Interv Cardiol. 2006; 19(3):258-63. DOI: 10.1111/j.1540-8183.2006.00139.x. View

3.
Yang C, Guo G, Yip H, Hsieh K, Fang C, Chen S . Bilateral cardiac catheterizations: the safety and feasibility of a superficial forearm venous and transradial arterial approach. Int Heart J. 2006; 47(1):21-7. DOI: 10.1536/ihj.47.21. View

4.
Shah S, Boyd G, Pyne C, Bilazarian S, Piemonte T, Jeon C . Right heart catheterization using antecubital venous access: feasibility, safety and adoption rate in a tertiary center. Catheter Cardiovasc Interv. 2013; 84(1):70-4. DOI: 10.1002/ccd.25249. View

5.
Cooper C, Cohen D, Blaesing L, Burket M, Basu A, Moore J . Effect of transradial access on quality of life and cost of cardiac catheterization: A randomized comparison. Am Heart J. 1999; 138(3 Pt 1):430-6. DOI: 10.1016/s0002-8703(99)70143-2. View