» Articles » PMID: 26991671

Tidal Volume Measurements in Infants: Opto-electronic Plethysmography Versus Pneumotachograph

Abstract

Tidal breathing measurements by Opto-Electronic Plethysmography (OEP) has been reported for infants limited to protocols with two chest wall compartments. Standard protocol for the analysis of adults, with three compartments of chest wall, has been unavailable for analysis of infants. We aimed to study the agreement of simultaneous measurements of tidal volume by OEP (VT,OEP ) and a heated pneumotachograph (PNT) (VT,PNT ) performed during sleeping in 20 infants (gestational age 35.1 ± 4.6 weeks) at 3-4 months postconceptual age with a three compartment protocol. From PNT and OEP measurements, tidal volume corrected (VT,PNT ) for ambient conditions were calculated with a total number of 200 breaths. The two methods were in good agreement with tidal volume mean difference of 0.02 ml and limit of agreement -4.11 to 4.08 ml (95%CI), no relationship was found between differences and means of OEP and PNT measurements. Pulmonary rib cage, abdominal rib cage and abdomen contributed by 12.4 ± 9.7%, 5.2 ± 5.1%, and 82.4 ± 11.4% to VT,OEP , respectively. The OEP experimental protocol based on 52 markers and a three-compartment model of the chest wall could be used in spontaneously sleeping infants. Pediatr Pulmonol. 2016;51:850-857. © 2016 Wiley Periodicals, Inc.

Citing Articles

The 4DBODY system as a new tool for chest mobility assessment in patients with ankylosing spondylitis.

Sadura-Sieklucka T, Szewczyk D, Liberacki P, Pasko S, Wojdasiewicz P, Targowski T Reumatologia. 2023; 61(5):353-359.

PMID: 37970113 PMC: 10634404. DOI: 10.5114/reum/173022.


Contactless Monitoring of Breathing Pattern and Thoracoabdominal Asynchronies in Preterm Infants Using Depth Cameras: A Feasibility Study.

Ottaviani V, Veneroni C, Dellaca R, Lavizzari A, Mosca F, Zannin E IEEE J Transl Eng Health Med. 2022; 10:4900708.

PMID: 35415022 PMC: 8989160. DOI: 10.1109/JTEHM.2022.3159997.


Advancements in Methods and Camera-Based Sensors for the Quantification of Respiration.

Rehouma H, Noumeir R, Essouri S, Jouvet P Sensors (Basel). 2020; 20(24).

PMID: 33348827 PMC: 7766256. DOI: 10.3390/s20247252.


Pediatric pulmonology year in review 2016: Part 2.

Auten R, Ren C, Yilmaz O, Noah T Pediatr Pulmonol. 2017; 52(9):1219-1225.

PMID: 28440920 PMC: 7167696. DOI: 10.1002/ppul.23719.


Spontaneous Breathing Pattern as Respiratory Functional Outcome in Children with Spinal Muscular Atrophy (SMA).

LoMauro A, Aliverti A, Mastella C, Arnoldi M, Banfi P, Baranello G PLoS One. 2016; 11(11):e0165818.

PMID: 27820869 PMC: 5098831. DOI: 10.1371/journal.pone.0165818.