» Articles » PMID: 26970975

A Novel System for Automated Propofol Sedation: Hybrid Sedation System (HSS)

Overview
Publisher Springer
Date 2016 Mar 14
PMID 26970975
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Closed-loop systems for propofol have been demonstrated to be safe and reliable for general anesthesia. However, no study has been conducted using a closed-loop system specifically designed for sedation in patients under spinal anesthesia. We developed an automatic anesthesia sedation system that allows for closed-loop delivery of propofol for sedation integrating a decision support system, called the hybrid sedation system (HSS). The objective of this study is to compare this system with standard practice. One hundred fifty patients were enrolled and randomly assigned to two groups: HSS-Group (N = 75), in which propofol was administered using a closed-loop system; Control Group (N = 75), in which propofol was delivered manually. The clinical performance of the propofol sedation control is defined as efficacy to maintain bispectral index (BIS) near 65. The clinical control was called 'Excellent', 'Good', 'Poor' and 'Inadequate' with BIS values within 10 %, from 11 to 20 %, 21 to 30 %, or greater than 30 % of the BIS target of 65, respectively. The controller performance was evaluated using Varvel's parameters. Data are presented as mean ± standard deviation, groups were compared using t test or Chi square test, P < 0.05. Clinical performance of sedation showed 'Excellent' control in the HSS-group for a significantly longer period of time (49 vs. 26 % in the control group, P < 0.0001). 'Poor' and 'Inadequate' sedation was significantly shorter in the HSS Group compared to the Control Group (11 and 10 % vs. 20 and 18 %, respectively, P < 0.0001). The novel, closed-loop system for propofol sedation showed better maintenance of the target BIS value compared to manual administration.

Citing Articles

Deep reinforcement learning for multi-targets propofol dosing.

Tu Z, Jeffries S, Pelletier E, Cafferty O, Morse J, Sinha A J Clin Monit Comput. 2025; .

PMID: 40045084 DOI: 10.1007/s10877-025-01269-z.


Comparison of time-series models for predicting physiological metrics under sedation.

Tu Z, Jeffries S, Morse J, Hemmerling T J Clin Monit Comput. 2024; .

PMID: 39470955 DOI: 10.1007/s10877-024-01237-z.


Outcomes of clinical decision support systems in real-world perioperative care: a systematic review and meta-analysis.

Cai J, Li P, Li W, Zhu T Int J Surg. 2024; 110(12):8057-8072.

PMID: 39037722 PMC: 11634111. DOI: 10.1097/JS9.0000000000001821.


Strengths-weaknesses-opportunities-threats analysis of artificial intelligence in anesthesiology and perioperative medicine.

Paiste H, Godwin R, Smith A, Berkowitz D, Melvin R Front Digit Health. 2024; 6:1316931.

PMID: 38444721 PMC: 10912557. DOI: 10.3389/fdgth.2024.1316931.


Performance of closed-loop systems for intravenous drug administration: a systematic review and meta-analysis of randomised controlled trials.

Spataru A, Eiben P, Pluddemann A J Clin Monit Comput. 2023; 38(1):5-18.

PMID: 37695449 DOI: 10.1007/s10877-023-01069-3.


References
1.
Absalom A, De Keyser R, Struys M . Closed loop anesthesia: are we getting close to finding the holy grail?. Anesth Analg. 2011; 112(3):516-8. DOI: 10.1213/ANE.0b013e318203f5ad. View

2.
MAYO C, Bickford R, FAULCONER Jr A . Electroencephalographically controlled anesthesia in abdominal surgery. J Am Med Assoc. 1950; 144(13):1081-3. DOI: 10.1001/jama.1950.02920130033008. View

3.
Absalom A, Sutcliffe N, Kenny G . Closed-loop control of anesthesia using Bispectral index: performance assessment in patients undergoing major orthopedic surgery under combined general and regional anesthesia. Anesthesiology. 2001; 96(1):67-73. DOI: 10.1097/00000542-200201000-00017. View

4.
Smith I, Monk T, White P, Ding Y . Propofol infusion during regional anesthesia: sedative, amnestic, and anxiolytic properties. Anesth Analg. 1994; 79(2):313-9. DOI: 10.1213/00000539-199408000-00020. View

5.
De Smet T, Struys M, Neckebroek M, Van den Hauwe K, Bonte S, Mortier E . The accuracy and clinical feasibility of a new bayesian-based closed-loop control system for propofol administration using the bispectral index as a controlled variable. Anesth Analg. 2008; 107(4):1200-10. DOI: 10.1213/ane.0b013e31817bd1a6. View