» Articles » PMID: 26964800

The Dark Art of Light Measurement: Accurate Radiometry for Low-level Light Therapy

Overview
Journal Lasers Med Sci
Publisher Springer
Date 2016 Mar 12
PMID 26964800
Citations 30
Authors
Affiliations
Soon will be listed here.
Abstract

Lasers and light-emitting diodes are used for a range of biomedical applications with many studies reporting their beneficial effects. However, three main concerns exist regarding much of the low-level light therapy (LLLT) or photobiomodulation literature; (1) incomplete, inaccurate and unverified irradiation parameters, (2) miscalculation of 'dose,' and (3) the misuse of appropriate light property terminology. The aim of this systematic review was to assess where, and to what extent, these inadequacies exist and to provide an overview of 'best practice' in light measurement methods and importance of correct light measurement. A review of recent relevant literature was performed in PubMed using the terms LLLT and photobiomodulation (March 2014-March 2015) to investigate the contemporary information available in LLLT and photobiomodulation literature in terms of reporting light properties and irradiation parameters. A total of 74 articles formed the basis of this systematic review. Although most articles reported beneficial effects following LLLT, the majority contained no information in terms of how light was measured (73%) and relied on manufacturer-stated values. For all papers reviewed, missing information for specific light parameters included wavelength (3%), light source type (8%), power (41%), pulse frequency (52%), beam area (40%), irradiance (43%), exposure time (16%), radiant energy (74%) and fluence (16%). Frequent use of incorrect terminology was also observed within the reviewed literature. A poor understanding of photophysics is evident as a significant number of papers neglected to report or misreported important radiometric data. These errors affect repeatability and reliability of studies shared between scientists, manufacturers and clinicians and could degrade efficacy of patient treatments. Researchers need a physicist or appropriately skilled engineer on the team, and manuscript reviewers should reject papers that do not report beam measurement methods and all ten key parameters: wavelength, power, irradiation time, beam area (at the skin or culture surface; this is not necessarily the same size as the aperture), radiant energy, radiant exposure, pulse parameters, number of treatments, interval between treatments and anatomical location. Inclusion of these parameters will improve the information available to compare and contrast study outcomes and improve repeatability, reliability of studies.

Citing Articles

Effectiveness of photobiomodulation with low-level lasers on the acceleration of orthodontic tooth movement: an umbrella review.

Jimenez-Pena O, Rios-Osorio N, Velandia-Palacio L, Gomez-Moreno G, Grajales M Evid Based Dent. 2024; .

PMID: 39616232 DOI: 10.1038/s41432-024-01090-8.


Potential of combined red and near-infrared photobiomodulation to mitigate pro-osteoclastic and inflammatory gene expression in human mandibular osteogenic cells.

Palmisano B, Del Vecchio A, Passaretti A, Stefano A, Miracolo G, Farinacci G Lasers Med Sci. 2024; 39(1):247.

PMID: 39349883 PMC: 11442520. DOI: 10.1007/s10103-024-04180-2.


Photobiomodulation versus fractional carbon dioxide laser for stria alba in phototype III-IV: a randomized controlled study.

Hafez V, Mahgoub D, Satour E, Mikhail M, El-Kalioby M Lasers Med Sci. 2024; 39(1):159.

PMID: 38890186 PMC: 11189306. DOI: 10.1007/s10103-024-04107-x.


Spectral characterization of a blue light-emitting micro-LED platform on skin-associated microbial chromophores.

Serrage H, Eling C, Alves P, Xie E, McBain A, Dawson M Biomed Opt Express. 2024; 15(5):3200-3215.

PMID: 38855662 PMC: 11161378. DOI: 10.1364/BOE.522867.


The power of light - From dental materials processing to diagnostics and therapeutics.

Hadis M, Shortall A, Palin W Biomater Investig Dent. 2024; 11:40308.

PMID: 38645925 PMC: 11022655. DOI: 10.2340/biid.v11.40308.


References
1.
Ilic S, Leichliter S, Streeter J, Oron A, DeTaboada L, Oron U . Effects of power densities, continuous and pulse frequencies, and number of sessions of low-level laser therapy on intact rat brain. Photomed Laser Surg. 2006; 24(4):458-66. DOI: 10.1089/pho.2006.24.458. View

2.
Larkin-Kaiser K, Christou E, Tillman M, George S, Borsa P . Near-infrared light therapy to attenuate strength loss after strenuous resistance exercise. J Athl Train. 2014; 50(1):45-50. PMC: 4299734. DOI: 10.4085/1062-6050-49.3.82. View

3.
Brito Vieira W, Bezerra R, Queiroz R, Maciel N, Parizotto N, Ferraresi C . Use of low-level laser therapy (808 nm) to muscle fatigue resistance: a randomized double-blind crossover trial. Photomed Laser Surg. 2014; 32(12):678-85. DOI: 10.1089/pho.2014.3812. View

4.
Leite S, de Andrade T, Masson-Meyers D, Leite M, Enwemeka C, Cipriani Frade M . Phototherapy promotes healing of cutaneous wounds in undernourished rats. An Bras Dermatol. 2014; 89(6):899-904. PMC: 4230658. DOI: 10.1590/abd1806-4841.20143356. View

5.
Karu T . Multiple roles of cytochrome c oxidase in mammalian cells under action of red and IR-A radiation. IUBMB Life. 2010; 62(8):607-10. DOI: 10.1002/iub.359. View