» Articles » PMID: 26964560

Validity of an Accelerometer-Based Activity Monitor System for Measuring Physical Activity in Frail Older Adults

Overview
Specialty Geriatrics
Date 2016 Mar 12
PMID 26964560
Citations 11
Authors
Affiliations
Soon will be listed here.
Abstract

This study aimed to investigate the validity of the accelerometer-based DynaPort system to detect physical activity in frail, older subjects. Eighteen home-dwelling subjects (Groningen Frailty Indicator [GFI] score ≥ 4, ≥ 75 years) were included. Activities in their home environment were simultaneously observed by two researchers and measured with the DynaPort system during six consecutive hours. Primary outcome measures were the sensitivity and specificity of the DynaPort for locomotion (90% considered as sufficient agreement). Other outcome measures were overall agreement, and sensitivity and specificity for other activities. Sensitivity and specificity for locomotion were 83.3% and 100.0%, respectively. Overall agreement was 74.6%. Sensitivity was sufficient for sitting (94.4%), but not for lying and standing (59.2% and 69.6%, respectively). Specificity was sufficient for lying and standing (100.0% and 93.3%, respectively), but not for sitting (80.7%). In conclusion, the DynaPort system is not a valid method for assessing physical activity in frail, older subjects.

Citing Articles

Concurrent Validity of Four Activity Monitors in Older Adults.

Wullems J, Verschueren S, Degens H, Morse C, Onambele-Pearson G Sensors (Basel). 2024; 24(3).

PMID: 38339613 PMC: 10856911. DOI: 10.3390/s24030895.


Validation of an accelerometer system for measuring physical activity and sedentary behavior in healthy children and adolescents.

Milther C, Winther L, Stahlhut M, Curtis D, Aadahl M, Kristensen M Eur J Pediatr. 2023; 182(8):3639-3647.

PMID: 37258775 PMC: 10460328. DOI: 10.1007/s00431-023-05014-z.


A Smart Shoe Insole to Monitor Frail Older Adults' Walking Speed: Results of Two Evaluation Phases Completed in a Living Lab and Through a 12-Week Pilot Study.

Piau A, Steinmeyer Z, Charlon Y, Courbet L, Rialle V, Lepage B JMIR Mhealth Uhealth. 2022; 9(7):e15641.

PMID: 36260404 PMC: 8406107. DOI: 10.2196/15641.


Quality Evaluation of Free-living Validation Studies for the Assessment of 24-Hour Physical Behavior in Adults via Wearables: Systematic Review.

Giurgiu M, Timm I, Becker M, Schmidt S, Wunsch K, Nissen R JMIR Mhealth Uhealth. 2022; 10(6):e36377.

PMID: 35679106 PMC: 9227659. DOI: 10.2196/36377.


Feasibility of Frailty Assessment Integrated with Cardiac Implantable Electronic Device Clinic Follow-up: A Pilot Investigation.

Albakri A, Orkaby A, Rosenberg M Gerontol Geriatr Med. 2021; 7:2333721420987342.

PMID: 33457464 PMC: 7797585. DOI: 10.1177/2333721420987342.