» Articles » PMID: 26948081

Effect of Screw-access Channels on the Fracture Resistance of 3 Types of Ceramic Implant-supported Crowns

Overview
Journal J Prosthet Dent
Specialty Dentistry
Date 2016 Mar 8
PMID 26948081
Citations 11
Authors
Affiliations
Soon will be listed here.
Abstract

Statement Of Problem: Access channels for retrieving ceramic implant-supported screw-retained crowns may decrease their fracture resistance.

Purpose: The purpose of this in vitro study was to evaluate the effect of screw-access channels on 3 types of ceramic implant-supported crowns.

Material And Methods: Sixty computer-aided designed and computer-aided manufactured (CAD-CAM) ceramic implant-supported screw-retained maxillary premolar crowns were fabricated, 30 with an occlusal screw-access channel and 30 without access channels. Each group was further divided into the following 3 subgroups of 10 specimens each: monolithic zirconia, veneered zirconia, and lithium disilicate. Identical milled titanium implant abutments were fabricated. Crowns were fabricated with standardized thicknesses and subjected to cyclic loading until failure occurred. Data analysis was performed using 1-way analysis of variance test of significance followed by Tukey honest significant difference (HSD) test (α=.05).

Results: No significant differences in fracture resistance were found between access channel groups and corresponding groups without access channels (P>.05). Among the subgroups, monolithic zirconia recorded the highest fatigue failure mean load values (2047.8 ±83.2 N for crowns with access channels and 2028.7 ±104.5 N for crowns without access channels), which was significantly higher (P<.05) than values for the lithium disilicate group (605.4 ±37.9 N for crowns with access channels and 615.3 ±76.6 N for crowns without access channels) and the veneered zirconia group (411 ±34.4 N for crowns with access channels and 461.2 ±72.7 N for crowns without access channels), which recorded the lowest fatigue failure load mean values.

Conclusions: Screw-access channels did not affect the fatigue failure load of monolithic zirconia, monolithic lithium disilicate, or veneered zirconia ceramic crowns. Monolithic zirconia crowns recorded significantly higher fatigue failure load among the 3 types of crowns tested.

Citing Articles

A conservative approach to localize loose implant screw through cemented crown: an in vitro experimental study.

Saeed K, Al-Zahawi A BMC Oral Health. 2024; 24(1):617.

PMID: 38807096 PMC: 11131170. DOI: 10.1186/s12903-024-04369-5.


Biomechanical behavior of different designs of hybrid abutment-restoration on the posterior crown: a finite element analysis.

Rocha A, Carvalho M, Bordin D, Del Bel Cury A, Lazari-Carvalho P Braz Dent J. 2023; 34(6):140-149.

PMID: 38133088 PMC: 10742363. DOI: 10.1590/0103-6440202305539.


Evaluation of the masking ability, marginal adaptation, and fracture resistance of screw-retained lithium disilicate implant-supported crowns cemented to titanium bases versus preparable abutments.

Kordi A, Salman A, Metwally N, Khamis M BMC Oral Health. 2023; 23(1):613.

PMID: 37649061 PMC: 10470172. DOI: 10.1186/s12903-023-03281-8.


The effect of aging on the fracture resistance of different types of screw-cement-retained implant-supported zirconia-based restorations.

Sahebi S, Giti R, Sherafati A PLoS One. 2022; 17(6):e0270527.

PMID: 35749553 PMC: 9232153. DOI: 10.1371/journal.pone.0270527.


Selection of 1-mm venting or 2.5-mm screw access holes on implant crowns based on cement extrusion and retention capacity.

Zhou H, Ye S, Liu M, Feng H, Wen C BMC Oral Health. 2022; 22(1):108.

PMID: 35366875 PMC: 8976311. DOI: 10.1186/s12903-022-02145-x.