» Articles » PMID: 26944922

Evaluation of a Low-Cost Aerosol Sensor to Assess Dust Concentrations in a Swine Building

Overview
Journal Ann Occup Hyg
Date 2016 Mar 6
PMID 26944922
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

Exposure to dust is a known occupational hazard in the swine industry, although efforts to measure exposures are labor intensive and costly. In this study, we evaluated a Dylos DC1100 as a low-cost (~$200) alternative to assess respirable dust concentrations in a swine building in winter. Dust concentrations were measured with collocated monitors (Dylos DC1100; an aerosol photometer, the pDR-1200; and a respirable sampler analyzed gravimetrically) placed in two locations within a swine farrowing building in winter for 18-24-h periods. The particle number concentrations measured with the DC1100 were converted to mass concentration using two methods: Physical Property Method and Regression Method. Raw number concentrations from the DC1100 were highly correlated to mass concentrations measured with the pDR-1200 with a coefficient of determination (R (2)) of 0.85, indicating that the two monitors respond similarly to respirable dust in this environment. Both methods of converting DC1100 number concentrations to mass concentrations yielded strong linear relationships relative to that measured with the pDR-1200 (Physical Property Method: slope = 1.03, R (2) = 0.72; Regression Method: slope = 0.72, R (2) = 0.73) and relative to that measured gravimetrically (Physical Property Method: slope = 1.08, R (2) = 0.64; Regression Method: slope = 0.75, R (2) = 0.62). The DC1100 can be used as a reasonable indicator of respirable mass concentrations within a CAFO and may have broader applicability to other agricultural and industrial settings.

Citing Articles

Validating and Comparing Highly Resolved Commercial "Off the Shelf" PM Monitoring Sensors with Satellite Based Hybrid Models, for Improved Environmental Exposure Assessment.

Lesser D, Katra I, Dorman M, Harari H, Kloog I Sensors (Basel). 2020; 21(1).

PMID: 33374352 PMC: 7796136. DOI: 10.3390/s21010063.


Investigating Measurement Variation of Modified Low-Cost Particle Sensors.

Collingwood S, Zmoos J, Pahler L, Wong B, Sleeth D, Handy R J Aerosol Sci. 2020; 135:21-32.

PMID: 32773886 PMC: 7413586. DOI: 10.1016/j.jaerosci.2019.04.017.


Occupational Exposure to Particulate Matter and Volatile Organic Compounds in Two Indoor Cannabis Production Facilities.

Silvey B, Seto E, Gipe A, Ghodsian N, Simpson C Ann Work Expo Health. 2020; 64(7):715-727.

PMID: 32696065 PMC: 7407603. DOI: 10.1093/annweh/wxaa067.


Investigation of multiple whole smoke dosimetry techniques using a VITROCELL®VC10® smoke exposure system.

Keyser B, Leverette R, Hollings M, Seymour A, Reeve L, Fields W Toxicol Rep. 2019; 6:1281-1288.

PMID: 31828014 PMC: 6889780. DOI: 10.1016/j.toxrep.2019.10.011.


Real-time particle monitoring of pesticide drift from an axial fan airblast orchard sprayer.

Blanco M, Fenske R, Kasner E, Yost M, Seto E, Austin E J Expo Sci Environ Epidemiol. 2018; 29(3):397-405.

PMID: 30425317 PMC: 6469994. DOI: 10.1038/s41370-018-0090-5.


References
1.
Anthony T, Altmaier R, Jones S, Gassman R, Park J, Peters T . Use of Recirculating Ventilation With Dust Filtration to Improve Wintertime Air Quality in a Swine Farrowing Room. J Occup Environ Hyg. 2015; 12(9):635-46. PMC: 4756717. DOI: 10.1080/15459624.2015.1029616. View

2.
Donham K, Haglind P, Peterson Y, Rylander R, Belin L . Environmental and health studies of farm workers in Swedish swine confinement buildings. Br J Ind Med. 1989; 46(1):31-7. PMC: 1009719. DOI: 10.1136/oem.46.1.31. View

3.
Benton-Vitz K, Volckens J . Evaluation of the pDR-1200 real-time aerosol monitor. J Occup Environ Hyg. 2008; 5(6):353-9. DOI: 10.1080/15459620802009919. View

4.
OShaughnessy P, Donham K, Peters T, Taylor C, Altmaier R, Kelly K . A task-specific assessment of Swine worker exposure to airborne dust. J Occup Environ Hyg. 2009; 7(1):7-13. PMC: 10466474. DOI: 10.1080/15459620903327970. View

5.
Semple S, Apsley A, MacCalman L . An inexpensive particle monitor for smoker behaviour modification in homes. Tob Control. 2012; 22(5):295-8. DOI: 10.1136/tobaccocontrol-2011-050401. View