Abstract

Introduction: This study investigates the accuracy of a heart rate (HR) measurement algorithm applied to a pulse wave. This was based on video signals recorded with a smartphone. The results of electrocardiographic HR and standard linear heart rate variability (HRV) analysis were used for reference.

Materials And Methods: On a total of 68 subjects, an electrocardiogram (ECG) and the pulse curve were simultaneously recorded on an Apple iPhone 4S. The HR was measured using an algorithm developed by the authors that works according to a method combining the detection of the steepest slope of every pulse wave with the correlation to an optimized pulse wave pattern.

Results: The results of the HR measured by pulse curves were extremely consistent (R > 0.99) with the HR measured on ECGs. For most standard linear HRV parameters as well, high correlations of R ≥ 0.90 in the analysis were achieved in the time and frequency domain.

Conclusion: In conclusion, the overall accuracy of HR and HRV indices of pulse wave analysis, based on video signals of a smartphone, with the developed algorithm was sufficient for preclinical screening applications.

Citing Articles

Performance of a medical smartband with photoplethysmography technology and artificial intelligence algorithm to detect atrial fibrillation.

Blok S, Gielen W, Piek M, Hoeksema W, Tulevski I, Somsen G Mhealth. 2025; 11:5.

PMID: 39944860 PMC: 11811644. DOI: 10.21037/mhealth-24-10.


A Scoping Review of the Use of Artificial Intelligence in the Identification and Diagnosis of Atrial Fibrillation.

Junior A, E Silva A, E Silva L, de Lima K, de Oliveira H J Pers Med. 2024; 14(11).

PMID: 39590561 PMC: 11595485. DOI: 10.3390/jpm14111069.


Parasystole?: A Smart Watch Investigation.

Alzahrani A, Pyevich V, Law I JACC Case Rep. 2024; 29(9):102314.

PMID: 38550909 PMC: 10973970. DOI: 10.1016/j.jaccas.2024.102314.


Validation of a Deep Learning Algorithm for Continuous, Real-Time Detection of Atrial Fibrillation Using a Wrist-Worn Device in an Ambulatory Environment.

Poh M, Battisti A, Cheng L, Lin J, Patwardhan A, Venkataraman G J Am Heart Assoc. 2023; 12(19):e030543.

PMID: 37750558 PMC: 10727259. DOI: 10.1161/JAHA.123.030543.


Smartphone and wearable detected atrial arrhythmias in Older Adults: Results of a fully digital European Case finding study.

Fabritz L, Connolly D, Czarnecki E, Dudek D, Guasch E, Haase D Eur Heart J Digit Health. 2023; 3(4):610-625.

PMID: 36710894 PMC: 9779806. DOI: 10.1093/ehjdh/ztac067.