Biomechanical Investigation of 'figure of 8' Flexor Tendon Repair Techniques
Overview
General Surgery
Authors
Affiliations
This biomechanical study compared the original Al-Qattan repair with other modifications postulated to reduce bulk and friction, thereby potentially improving outcome. A total of 32 cadaveric digits with intact flexor apparatus were used. In each digit, the flexor digitorum profundus and flexor digitorum superficialis tendons were cut cleanly in Zone 2. We tested Al-Qattan's technique along with three modifications using stronger suture material and varying the number of strands across the repair site. Of the four repair techniques, the modified Al-Qattan's technique using two 'figure of 8' 4-0 Fiberwire core sutures (Group 4) had the best balance of ultimate tensile strength (50.9 N), 2 mm gapping force (38 N) and friction. The modified technique provided a stronger repair for early active mobilization and has less friction than the originally described repair.
Schellnegger M, Lin A, Holzer-Geissler J, Haenel A, Pirrung F, Hecker A J Clin Med. 2024; 13(19).
PMID: 39407826 PMC: 11477230. DOI: 10.3390/jcm13195766.
In Vitro Biomechanical Study on the "Figure-of-Eight" and Kessler Sutures in Swine Flexor Tendons.
Kawachi D, Deienno F, Varanda D, Cortopassi A, Sardenberg T Rev Bras Ortop (Sao Paulo). 2020; 55(4):445-447.
PMID: 32904827 PMC: 7458735. DOI: 10.1055/s-0039-1700828.