» Articles » PMID: 26924520

Outcomes for Patients With Diabetes After Continuous-Flow Left Ventricular Assist Device Implantation

Overview
Journal J Card Fail
Date 2016 Mar 1
PMID 26924520
Citations 9
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Diabetes mellitus (DM) is a risk factor for mortality among patients with heart failure as well as for patients who undergo cardiothoracic surgery. However it is unknown whether DM is associated with increased mortality or major complications during continuous-flow left ventricular assist device (CF-LVAD) support.

Methods And Results: We retrospectively reviewed 300 consecutive adults who received CF-LVADs at a single center in the years 2006-2013; 129 patients had DM before LVAD, as defined by American Diabetes Association criteria (HbA1c ≥6.5% and/or taking DM medications). Compared with the non-DM group, DM patients were older, with a higher pre-LVAD body mass index, more ischemic heart failure etiology, and higher pre-LVAD creatinine. Ninety-three patients died on LVAD support, 43 with DM and 50 without DM (P = .4526). After control for 9 covariates in a Cox proportional hazards model, DM was unassociated with all-cause mortality (hazard ratio 0.883, 95% confidence interval 0.571-1.366; P = .5768). Diabetes was also unassociated with the adverse event end points of stroke/transient ischemic attack, intracerebral hemorrhage, pump thrombosis, and device-related infections.

Conclusions: Diabetes is common in LVAD recipients (43% of the present cohort) but does not increase mortality or rates of major adverse events during CF-LVAD support.

Citing Articles

Impact of Diabetes Mellitus on Outcomes in Patients with Left Ventricular Assist Devices.

Crugnola W, Cinquina A, Mattimore D, Bitzas S, Schwartz J, Zaidi S Biomedicines. 2024; 12(7).

PMID: 39062177 PMC: 11275105. DOI: 10.3390/biomedicines12071604.


Impact of Diabetes and Glycemia on Cardiac Improvement and Adverse Events Following Mechanical Circulatory Support.

Kyriakopoulos C, Taleb I, Tseliou E, Sideris K, Hamouche R, Maneta E J Am Heart Assoc. 2024; 13(14):e032936.

PMID: 38989825 PMC: 11292740. DOI: 10.1161/JAHA.123.032936.


Patient factors associated with left ventricular assist device infections: A scoping review.

Pienta M, Shore S, Watt T, Yost G, Townsend W, Cabrera L J Heart Lung Transplant. 2022; 41(4):425-433.

PMID: 35168899 PMC: 9974018. DOI: 10.1016/j.healun.2022.01.011.


HFA of the ESC position paper on the management of LVAD-supported patients for the non-LVAD specialist healthcare provider Part 3: at the hospital and discharge.

Gustafsson F, Ben Avraham B, Chioncel O, Hasin T, Grupper A, Shaul A ESC Heart Fail. 2021; 8(6):4425-4443.

PMID: 34585525 PMC: 8712918. DOI: 10.1002/ehf2.13590.


2019 EACTS Expert Consensus on long-term mechanical circulatory support.

Potapov E, Antonides C, Crespo-Leiro M, Combes A, Farber G, Hannan M Eur J Cardiothorac Surg. 2019; 56(2):230-270.

PMID: 31100109 PMC: 6640909. DOI: 10.1093/ejcts/ezz098.