» Articles » PMID: 26833864

Transcranial Doppler Versus Transthoracic Echocardiography for the Detection of Patent Foramen Ovale in Patients with Cryptogenic Cerebral Ischemia: A Systematic Review and Diagnostic Test Accuracy Meta-analysis

Abstract

Objective: Patent foramen ovale (PFO) can be detected in up to 43% of patients with cryptogenic cerebral ischemia undergoing investigation with transesophageal echocardiography (TEE). The diagnostic value of transthoracic echocardiography (TTE) in the detection of PFO in patients with cryptogenic ischemic stroke or transient ischemic attack has not been compared with that of transcranial Doppler (TCD) using a comprehensive meta-analytical approach.

Methods: We performed a systematic literature review to identify all prospective observational studies of patients with cryptogenic cerebral ischemia that provided both sensitivity and specificity measures of TTE, TCD, or both compared to the gold standard of TEE.

Results: Our literature search identified 35 eligible studies including 3,067 patients. The pooled sensitivity and specificity for TCD was 96.1% (95% confidence interval [CI] = 93.0-97.8%) and 92.4% (95% CI = 85.5-96.1%), whereas the respective measures for TTE were 45.1% (95% CI = 30.8-60.3%) and 99.6% (95% CI = 96.5-99.9%). TTE was superior in terms of higher positive likelihood ratio values (LR+ = 106.61, 95% CI = 15.09-753.30 for TTE vs LR+ = 12.62, 95% CI = 6.52-24.43 for TCD; p = 0.043), whereas TCD demonstrated lower negative likelihood values (LR- = 0.04, 95% CI = 0.02-0.08) compared to TTE (LR- = 0.55, 95% CI = 0.42-0.72; p < 0.001). Finally, the area under the summary receiver operating curve (AUC) was significantly greater (p < 0.001) in TCD (AUC = 0.98, 95% CI = 0.97-0.99) compared to TTE studies (AUC = 0.86, 95% CI = 0.82-0.89).

Interpretation: TCD is more sensitive but less specific compared to TTE for the detection of PFO in patients with cryptogenic cerebral ischemia. The overall diagnostic yield of TCD appears to outweigh that of TTE.

Citing Articles

Enhancing the diagnostic efficacy of right-to-left shunt using robot-assisted transcranial Doppler: a quality improvement project.

Shah R, Devlin C, Gao L, Ledford S, Ramjee V, Madan V Front Neurol. 2025; 16:1512061.

PMID: 40070666 PMC: 11894734. DOI: 10.3389/fneur.2025.1512061.


Incorporation of robotic automated transcranial Doppler to screen for patent foramen ovale (PFO) and quantify right-to-left shunt severity in the evaluation of ischemic stroke patients for etiology and PFO management.

Chang I, Pirahanchi Y, Izaguirre S, Rodriguez R, Wicknick A Front Neurol. 2025; 15:1481817.

PMID: 40017730 PMC: 11866324. DOI: 10.3389/fneur.2024.1481817.


Genetic variation in patent foramen ovale: a case-control genome-wide association study.

Dong B, Li Y, Ai F, Geng J, Tang T, Peng W Front Genet. 2025; 15:1523304.

PMID: 39872005 PMC: 11769951. DOI: 10.3389/fgene.2024.1523304.


Impact of patent foramen ovale with left-to-right shunt on atrial fibrillation ablation in young patients.

Wang T, Jin X, Lu Y, Qi X, Chen C, Yang J Indian Heart J. 2024; 76(4):286-290.

PMID: 39096964 PMC: 11451409. DOI: 10.1016/j.ihj.2024.07.010.


Congenital heart disease: types, pathophysiology, diagnosis, and treatment options.

Meng X, Song M, Zhang K, Lu W, Li Y, Zhang C MedComm (2020). 2024; 5(7):e631.

PMID: 38974713 PMC: 11224996. DOI: 10.1002/mco2.631.