» Articles » PMID: 26788332

Clinical and Programming Pattern of Patients with Impending Deep Brain Stimulation Power Failure: a Retrospective Chart Review

Overview
Publisher Biomed Central
Date 2016 Jan 21
PMID 26788332
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Background: It is important to prevent complications of implanted pulse generators (IPG) depletion by replacing the IPG in time.

Methods: We reviewed the charts of all patients with deep brain stimulation treated movement disorders who were seen at our institution over a period of 6 months. Among these, we retained for analyses those who had undergone IPG replacement within the previous 3 years.

Results: A total of 55 IPG replacements (from 38 patients) were reviewed. Electrodes were implanted in the subthalamic nucleus in all Parkinson's disease patients, in the ventral intermedius nucleus of the thalamus in all essential tremor patients and in the globus pallidus interna in all dystonia patients. Replacements were preceded by a voltage increase due to worsened symptoms in 27.3% (15/55); 25.5% (14/55) had full IPG depletion or had too low IPG reserve to allow for any voltage adjustment; and 21.7% (12/55) did not get a needed voltage increase either for safety reasons (eg: concern for increase in falls with higher voltages) or because the surgery date for IPG replacement was close. Only 25.5% (14/55) remained clinically well-controlled prior to IPG replacement, all of whom had IPG longevity estimates available. Clinical deterioration was noted prior to IPG replacement in 100% of patients without available longevity estimates versus 61% of patients with available longevity estimates (p < 0.001).

Conclusion: Despite best efforts, clinical deterioration prior to IPG replacement can be seen frequently. Routine estimation of IPG life, along with symptom assessment at every follow-up visit may prevent it.

Citing Articles

A Study of Battery Replacement Characteristics of Patients With Parkinson's Disease and Factors Influencing Battery Drain.

Sharma P, Holla V, Gurram S, Kamble N, Yadav R, Srinivas D Ann Indian Acad Neurol. 2023; 26(4):580-583.

PMID: 37970272 PMC: 10645253. DOI: 10.4103/aian.aian_62_23.


Effects of rasagiline combined with levodopa and benserazide hydrochloride on motor function and homocysteine and IGF-1 levels in elderly patients with Parkinson's disease.

Yang Y, Gao F, Gao L, Miao J BMC Neurol. 2023; 23(1):360.

PMID: 37803329 PMC: 10557206. DOI: 10.1186/s12883-023-03411-3.


Depleting implanted pulse generator (IPG) battery voltage is associated with worsening clinical symptoms in movement disorder patients receiving Deep brain stimulation (DBS).

Hamed M, Ba F, Suchowersky O, Sankar T Clin Park Relat Disord. 2021; 1:98-99.

PMID: 34316609 PMC: 8288559. DOI: 10.1016/j.prdoa.2019.11.001.


Patient Experience with Rechargeable Implantable Pulse Generator Deep Brain Stimulation for Movement Disorders.

Mitchell K, Volz M, Lee A, San Luciano M, Wang S, Starr P Stereotact Funct Neurosurg. 2019; 97(2):113-119.

PMID: 31288242 PMC: 6689445. DOI: 10.1159/000500993.


Sudden loss of the deep brain stimulation effect with high impedance without macroscopic fracture: a case report and review of the published literature.

Yang H, Yun J, Kim Y, Lim Y, Kim H, Paek S Neuropsychiatr Dis Treat. 2015; 11:1799-803.

PMID: 26229475 PMC: 4516336. DOI: 10.2147/NDT.S86120.

References
1.
Okun M, Tagliati M, Pourfar M, Fernandez H, Rodriguez R, Alterman R . Management of referred deep brain stimulation failures: a retrospective analysis from 2 movement disorders centers. Arch Neurol. 2005; 62(8):1250-5. DOI: 10.1001/archneur.62.8.noc40425. View

2.
Isaias I, Alterman R, Tagliati M . Deep brain stimulation for primary generalized dystonia: long-term outcomes. Arch Neurol. 2009; 66(4):465-70. DOI: 10.1001/archneurol.2009.20. View

3.
Fakhar K, Hastings E, Butson C, Foote K, Zeilman P, Okun M . Management of deep brain stimulator battery failure: battery estimators, charge density, and importance of clinical symptoms. PLoS One. 2013; 8(3):e58665. PMC: 3594176. DOI: 10.1371/journal.pone.0058665. View

4.
Rawal P, Almeida L, Smelser L, Huang H, Guthrie B, Walker H . Shorter pulse generator longevity and more frequent stimulator adjustments with pallidal DBS for dystonia versus other movement disorders. Brain Stimul. 2014; 7(3):345-9. PMC: 4011995. DOI: 10.1016/j.brs.2014.01.008. View

5.