» Articles » PMID: 26767969

An Open Source Software for Analysis of Dynamic Contrast Enhanced Magnetic Resonance Images: UMMPerfusion Revisited

Overview
Journal BMC Med Imaging
Publisher Biomed Central
Specialty Radiology
Date 2016 Jan 16
PMID 26767969
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Perfusion imaging has become an important image based tool to derive the physiological information in various applications, like tumor diagnostics and therapy, stroke, (cardio-) vascular diseases, or functional assessment of organs. However, even after 20 years of intense research in this field, perfusion imaging still remains a research tool without a broad clinical usage. One problem is the lack of standardization in technical aspects which have to be considered for successful quantitative evaluation; the second problem is a lack of tools that allow a direct integration into the diagnostic workflow in radiology.

Results: Five compartment models, namely, a one compartment model (1CP), a two compartment exchange (2CXM), a two compartment uptake model (2CUM), a two compartment filtration model (2FM) and eventually the extended Toft's model (ETM) were implemented as plugin for the DICOM workstation OsiriX. Moreover, the plugin has a clean graphical user interface and provides means for quality management during the perfusion data analysis. Based on reference test data, the implementation was validated against a reference implementation. No differences were found in the calculated parameters.

Conclusion: We developed open source software to analyse DCE-MRI perfusion data. The software is designed as plugin for the DICOM Workstation OsiriX. It features a clean GUI and provides a simple workflow for data analysis while it could also be seen as a toolbox providing an implementation of several recent compartment models to be applied in research tasks. Integration into the infrastructure of a radiology department is given via OsiriX. Results can be saved automatically and reports generated automatically during data analysis ensure certain quality control.

Citing Articles

Motion-compensated image reconstruction for improved kidney function assessment using dynamic contrast-enhanced MRI.

Ariyurek C, Kocanaogullari A, Afacan O, Kurugol S NMR Biomed. 2024; 37(6):e5116.

PMID: 38359842 PMC: 11721693. DOI: 10.1002/nbm.5116.


Long-term evaluation of uterine fibroid embolisation using MRI perfusion parameters and patient questionnaires: preliminary results.

Sadick M, Hofmann L, Weiss C, Tuschy B, Schonberg S, Zollner F BMC Med Imaging. 2022; 22(1):214.

PMID: 36471287 PMC: 9724260. DOI: 10.1186/s12880-022-00926-y.


Hyperpolarized [1- C]pyruvate combined with the hyperinsulinaemic euglycaemic and hypoglycaemic clamp technique in skeletal muscle in a large animal model.

Bengtsen M, Hansen E, Tougaard R, Lyhne M, Rittig N, Stoy J Exp Physiol. 2021; 106(12):2412-2422.

PMID: 34705304 PMC: 9298727. DOI: 10.1113/EP089782.


Analysis Protocol for Dynamic Contrast Enhanced (DCE) MRI of Renal Perfusion and Filtration.

Zollner F, Dastru W, Irrera P, Longo D, Bennett K, Beeman S Methods Mol Biol. 2021; 2216:637-653.

PMID: 33476028 PMC: 9703217. DOI: 10.1007/978-1-0716-0978-1_38.


Dynamic Contrast Enhanced (DCE) MRI-Derived Renal Perfusion and Filtration: Experimental Protocol.

Irrera P, Consolino L, Dastru W, Pedersen M, Zollner F, Longo D Methods Mol Biol. 2021; 2216:429-441.

PMID: 33476015 PMC: 9703867. DOI: 10.1007/978-1-0716-0978-1_25.


References
1.
Sourbron S . Compartmental modelling for magnetic resonance renography. Z Med Phys. 2010; 20(2):101-14. DOI: 10.1016/j.zemedi.2009.10.010. View

2.
Koh T, Bisdas S, Koh D, Thng C . Fundamentals of tracer kinetics for dynamic contrast-enhanced MRI. J Magn Reson Imaging. 2011; 34(6):1262-76. DOI: 10.1002/jmri.22795. View

3.
Zollner F, Weisser G, Reich M, Kaiser S, Schoenberg S, Sourbron S . UMMPerfusion: an open source software tool towards quantitative MRI perfusion analysis in clinical routine. J Digit Imaging. 2012; 26(2):344-52. PMC: 3597952. DOI: 10.1007/s10278-012-9510-6. View

4.
Michaely H, Sourbron S, Dietrich O, Attenberger U, Reiser M, Schoenberg S . Functional renal MR imaging: an overview. Abdom Imaging. 2006; 32(6):758-71. DOI: 10.1007/s00261-006-9150-8. View

5.
Heye T, Davenport M, Horvath J, Feuerlein S, Breault S, Bashir M . Reproducibility of dynamic contrast-enhanced MR imaging. Part I. Perfusion characteristics in the female pelvis by using multiple computer-aided diagnosis perfusion analysis solutions. Radiology. 2012; 266(3):801-11. DOI: 10.1148/radiol.12120278. View