» Articles » PMID: 26753703

Evaluation of a Portable Microchip Electrophoresis Fluorescence Detection System for the Analysis of Amino Acid Neurotransmitters in Brain Dialysis Samples

Overview
Journal Anal Sci
Publisher Springer
Specialty Chemistry
Date 2016 Jan 13
PMID 26753703
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

A portable fluorescence detection system for use with microchip electrophoresis was developed and compared to a benchtop system. Using this system, six neuroactive amines commonly found in brain dialysate (arginine, citrulline, taurine, histamine, glutamate, and aspartate) were derivatized offline with naphthalene-2,3-dicarboxaldehyde/cyanide, separated electrophoretically, and detected by fluorescence. The limits of detection for the analytes of interest were 50 - 250 nM for the benchtop system and 250 nM - 1.3 μM for the portable system, both of which were adequate for most analyte detection in brain microdialysis samples. The portable system was then demonstrated for the detection of the same six amines in a rat brain microdialysis sample.

Citing Articles

Green Microfluidic Method for Sustainable and High-Speed Analysis of Basic Amino Acids in Nutritional Supplements.

Pukles I, Pager C, Sakac N, Sarkanj B, Markovic D, Sakac M Molecules. 2024; 29(23).

PMID: 39683714 PMC: 11643986. DOI: 10.3390/molecules29235554.


Advancements in Brain Research: The In Vivo/In Vitro Electrochemical Detection of Neurochemicals.

Xu X, Zuo Y, Chen S, Hatami A, Gu H Biosensors (Basel). 2024; 14(3).

PMID: 38534232 PMC: 10968235. DOI: 10.3390/bios14030125.


Biological applications of microchip electrophoresis with amperometric detection: in vivo monitoring and cell analysis.

Schilly K, Gunawardhana S, Wijesinghe M, Lunte S Anal Bioanal Chem. 2020; 412(24):6101-6119.

PMID: 32347360 PMC: 8130646. DOI: 10.1007/s00216-020-02647-z.


Progress toward the development of a microchip electrophoresis separation-based sensor with electrochemical detection for on-line in vivo monitoring of catecholamines.

Gunawardhana S, Bulgakova G, Barybin A, Thomas S, Lunte S Analyst. 2020; 145(5):1768-1776.

PMID: 31915763 PMC: 7127871. DOI: 10.1039/c9an01980d.


Detection of Epidermal Growth Factor Receptor Gene Status via a DNA Electrochemical Biosensor Based on Lambda Exonuclease-assisted Signal Amplification.

Weng X, Xu X, Huang P, Liu Z, Liu A, Chen W Anal Sci. 2019; 36(6):697-701.

PMID: 31866610 DOI: 10.2116/analsci.19P422.


References
1.
Culbertson C, Tugnawat Y, Meyer A, Roman G, Ramsey J, Gonda S . Microchip separations in reduced-gravity and hypergravity environments. Anal Chem. 2005; 77(24):7933-40. DOI: 10.1021/ac051198e. View

2.
Coltro W, Lunte S, Carrilho E . Comparison of the analytical performance of electrophoresis microchannels fabricated in PDMS, glass, and polyester-toner. Electrophoresis. 2008; 29(24):4928-37. PMC: 2672913. DOI: 10.1002/elps.200700897. View

3.
Kirkman M, Citerio G, Smith M . The intensive care management of acute ischemic stroke: an overview. Intensive Care Med. 2014; 40(5):640-53. DOI: 10.1007/s00134-014-3266-z. View

4.
Persson L, Hillered L . Chemical monitoring of neurosurgical intensive care patients using intracerebral microdialysis. J Neurosurg. 1992; 76(1):72-80. DOI: 10.3171/jns.1992.76.1.0072. View

5.
Zhou S, Zuo H, Stobaugh J, Lunte C, Lunte S . Continuous in vivo monitoring of amino acid neurotransmitters by microdialysis sampling with on-line derivatization and capillary electrophoresis separation. Anal Chem. 1995; 67(3):594-9. DOI: 10.1021/ac00099a017. View