Abstract

The leading indication for revision total hip arthroplasty (THA) remains aseptic loosening owing to wear. The younger, more active patients currently undergoing THA present unprecedented demands on the bearings. Ceramic-on-ceramic (CoC) bearings have consistently shown the lowest rates of wear. The recent advances, especially involving alumina/zirconia composite ceramic, have led to substantial improvements and good results in vitro. Alumina/zirconia composite ceramics are extremely hard, scratch resistant and biocompatible. They offer a low co-efficient of friction and superior lubrication and lower rates of wear compared with other bearings. The major disadvantage is the risk of fracture of the ceramic. The new composite ceramic has reduced the risk of fracture of the femoral head to 0.002%. The risk of fracture of the liner is slightly higher (0.02%). Assuming that the components are introduced without impingement, CoC bearings have major advantages over other bearings. Owing to the superior hardness, they produce less third body wear and are less vulnerable to intra-operative damage. The improved tribology means that CoC bearings are an excellent choice for young, active patients requiring THA.

Citing Articles

Pseudotumor in Ceramic-on-Ceramic Total Hip Arthroplasty: A Case Report.

Piper D, Saloway J, Jeys L, Hussain S Cureus. 2024; 16(10):e71518.

PMID: 39553120 PMC: 11563772. DOI: 10.7759/cureus.71518.


Comparison of 5-year cup and stem migration between ceramic-on-ceramic and ceramic-on-polyethylene bearing in press-fit total hip arthroplasty: a randomised controlled trial using radiostereometric analysis.

Klaassen A, van Loon J, Willigenburg N, Koster L, Kaptein B, van der Hulst V Hip Int. 2024; 34(6):701-716.

PMID: 39160668 PMC: 11629593. DOI: 10.1177/11207000241265653.


Revision in Ceramic-on-Ceramic and Ceramic-on-Polyethylene Bearing in Primary Total Hip Arthroplasty with Press-fit Cups: A Systematic Review and Meta-analysis of Different Methodological Study Designs.

van Loon J, de Graeff J, Sierevelt I, Opdam K, Poolman R, Kerkhoffs G Arch Bone Jt Surg. 2022; 10(11):916-936.

PMID: 36561219 PMC: 9749123. DOI: 10.22038/ABJS.2022.59354.2933.


A Review on Biomaterials for Orthopaedic Surgery and Traumatology: From Past to Present.

Szczesny G, Kopec M, Politis D, Kowalewski Z, Lazarski A, Szolc T Materials (Basel). 2022; 15(10).

PMID: 35629649 PMC: 9145924. DOI: 10.3390/ma15103622.


Higher risk of 2-year cup revision of ceramic-on-ceramic versus ceramic-on-polyethylene bearing: analysis of 33,454 primary press-fit total hip arthroplasties registered in the Dutch Arthroplasty Register (LROI).

van Loon J, Sierevelt I, Spekenbrink-Spooren A, Opdam K, Poolman R, Kerkhoffs G Hip Int. 2022; 33(2):280-287.

PMID: 34974763 PMC: 9978866. DOI: 10.1177/11207000211064975.