» Articles » PMID: 2673059

Limitations of Patient Triggered Ventilation in Neonates

Overview
Journal Arch Dis Child
Specialty Pediatrics
Date 1989 Jul 1
PMID 2673059
Citations 13
Authors
Affiliations
Soon will be listed here.
Abstract

The practicality of long term patient triggered ventilation using airflow changes was assessed in 22 infants with a median gestational age of 29 weeks (range 25-33 weeks). Inflation time during patient triggered ventilation was limited to 0.4 seconds or less. Initially it was associated with improvements in oxygenation in most infants. Patient triggered ventilation was maintained till final extubation in 13 of the infants without complications. Only one infant developed a pneumothorax, but in the remaining eight infants (who tended to be less mature (p less than 0.01) it had to be discontinued after only a few hours. Predictors of failure of patient triggered ventilation at one hour were both a lack of improvement in oxygenation, and a relatively slow triggering rate that was related to gestational age. We conclude that long term patient triggered ventilation is practical for preterm neonates, but only for those more mature than 28 weeks' gestational age.

Citing Articles

Synchronized mechanical ventilation for respiratory support in newborn infants.

Greenough A, Rossor T, Sundaresan A, Murthy V, Milner A Cochrane Database Syst Rev. 2016; 9:CD000456.

PMID: 27581993 PMC: 6457687. DOI: 10.1002/14651858.CD000456.pub5.


Randomised controlled trial of patient triggered and conventional fast rate ventilation in neonatal respiratory distress syndrome.

Beresford M, Shaw N, Manning D Arch Dis Child Fetal Neonatal Ed. 2000; 82(1):F14-8.

PMID: 10634835 PMC: 1721039. DOI: 10.1136/fn.82.1.f14.


Advances in neonatal conventional ventilation.

Sinha S, Donn S Arch Dis Child Fetal Neonatal Ed. 1996; 75(2):F135-40.

PMID: 8949700 PMC: 1061180. DOI: 10.1136/fn.75.2.f135.


Determinants of oxygenation during high frequency oscillation.

Chan V, Greenough A Eur J Pediatr. 1993; 152(4):350-3.

PMID: 8482289 DOI: 10.1007/BF01956752.


Long term trigger ventilation in neonatal respiratory distress syndrome.

de Boer R, Jones A, Ward P, Baumer J Arch Dis Child. 1993; 68(3 Spec No):308-11.

PMID: 8466268 PMC: 1590383. DOI: 10.1136/adc.68.3_spec_no.308.


References
1.
Epstein R . The sensitivities and response times of ventilatory assistors. Anesthesiology. 1971; 34(4):321-6. DOI: 10.1097/00000542-197104000-00007. View

2.
Greenough A . The premature infant's respiratory response to mechanical ventilation. Early Hum Dev. 1988; 17(1):1-5. DOI: 10.1016/s0378-3782(88)80051-3. View

3.
Greenough A, Morley C, Davis J . Respiratory reflexes in ventilated premature babies. Early Hum Dev. 1983; 8(1):65-75. DOI: 10.1016/0378-3782(83)90035-x. View

4.
Greenough A, Wood S, Morley C, Davis J . Pancuronium prevents pneumothoraces in ventilated premature babies who actively expire against positive pressure inflation. Lancet. 1984; 1(8367):1-3. DOI: 10.1016/s0140-6736(84)90177-6. View

5.
Boros S, Bing D, Mammel M, Hagen E, Gordon M . Using conventional infant ventilators at unconventional rates. Pediatrics. 1984; 74(4):487-92. View