» Articles » PMID: 26730375

Cone-beam Computed Tomography: Time to Move from ALARA to ALADA

Overview
Specialty Radiology
Date 2016 Jan 6
PMID 26730375
Citations 81
Authors
Affiliations
Soon will be listed here.
Abstract

Cone-beam computed tomography (CBCT) is routinely recommended for dental diagnosis and treatment planning. CBCT exposes patients to less radiation than does conventional CT. Still, lack of proper education among dentists and specialists is resulting in improper referral for CBCT. In addition, aiming to generate high-quality images, operators may increase the radiation dose, which can expose the patient to unnecessary risk. This letter advocates appropriate radiation dosing during CBCT to the benefit of both patients and dentists, and supports moving from the concept of "as low as reasonably achievable" (ALARA) to "as low as diagnostically acceptable" (ALADA).

Citing Articles

Comparison of cone-beam computed tomography with photon-counting detector computed tomography for dental implant surgery.

Al-Haj Husain A, Mergen V, Valdec S, Al-Haj Husain N, Stadlinger B, Essig H Int J Implant Dent. 2025; 11(1):21.

PMID: 40080282 PMC: 11906956. DOI: 10.1186/s40729-025-00611-z.


Pediatric Treatment of Anterior-Upper-Single Dental Crossbite Using a Versatile Sagittal Screw System: A Case Series.

Giudice A, Polizzi A Pediatr Rep. 2025; 17(1).

PMID: 39997618 PMC: 11858000. DOI: 10.3390/pediatric17010011.


Principles of radiological protection and application of ALARA, ALADA, and ALADAIP: a critical review.

Mendonca R, Estrela C, Bueno M, Carvalho T, Estrela L, Chilvarquer I Braz Oral Res. 2025; 39:e14.

PMID: 39936713 PMC: 11808696. DOI: 10.1590/1807-3107bor-2025.vol39.014.


Validation of novel measurement protocols proposed for the standardized assessment of crestal bone levels: A cone-beam computed tomography study.

Fahd A, Hussien A, Ellabban M, Shatat Z Imaging Sci Dent. 2025; 54(4):354-361.

PMID: 39744555 PMC: 11685304. DOI: 10.5624/isd.20240073.


Three-dimensional digital imaging analysis of the palatal bone thickness for orthodontic mini-implant insertion - determination of the safe zone and angulation.

Schubert H, Matta R, Seidel A, Adler W, Wichmann M, Kesting M BMC Oral Health. 2024; 24(1):1448.

PMID: 39609793 PMC: 11603675. DOI: 10.1186/s12903-024-05229-y.


References
1.
Brenner D, Hall E . Computed tomography--an increasing source of radiation exposure. N Engl J Med. 2007; 357(22):2277-84. DOI: 10.1056/NEJMra072149. View

2.
Carter L, Farman A, Geist J, Scarfe W, Angelopoulos C, Nair M . American Academy of Oral and Maxillofacial Radiology executive opinion statement on performing and interpreting diagnostic cone beam computed tomography. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2008; 106(4):561-2. DOI: 10.1016/j.tripleo.2008.07.007. View

3.
Choi E, Ford N . Measuring absorbed dose for i-CAT CBCT examinations in child, adolescent and adult phantoms. Dentomaxillofac Radiol. 2015; 44(6):20150018. PMC: 4628404. DOI: 10.1259/dmfr.20150018. View

4.
Brown J, Jacobs R, Levring Jaghagen E, Lindh C, Baksi G, Schulze D . Basic training requirements for the use of dental CBCT by dentists: a position paper prepared by the European Academy of DentoMaxilloFacial Radiology. Dentomaxillofac Radiol. 2013; 43(1):20130291. PMC: 3887486. DOI: 10.1259/dmfr.20130291. View

5.
Ludlow J, Davies-Ludlow L, Brooks S, Howerton W . Dosimetry of 3 CBCT devices for oral and maxillofacial radiology: CB Mercuray, NewTom 3G and i-CAT. Dentomaxillofac Radiol. 2006; 35(4):219-26. DOI: 10.1259/dmfr/14340323. View