» Articles » PMID: 26705531

Comparison of Tracheal Intubation Using the Storz's C-Mac D-blade(TM) Video-Laryngoscope Aided by Truflex(TM) Articulating Stylet and the Portex(TM) Intubating Stylet

Overview
Journal Anesth Pain Med
Publisher Brieflands
Date 2015 Dec 26
PMID 26705531
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Tracheal intubation using Storz's C-Mac D-blade(TM) videolaryngoscope is associated with difficult negotiation of the tracheal tube into the glottis due to steep angulation of its blade.

Objectives: In this study, we hypothesized that Truflex(TM) articulating stylet with its ability to dynamically tailor the ETT shape to patients' oropharyngeal anatomy would be better suited to the D-blade angulation and ease tracheal intubation compared to Portex(TM) intubation stylet.

Patients And Methods: Following approval by the Ethical Issues Committee and informed consent, 218 ASA I and II patients of either sex were enrolled in this interventional, single-blind, randomized controlled trial. Tracheal intubation was performed following a uniform general anesthetic technique using the Storz's C-Mac D-blade(TM) videolaryngoscope aided by either Truflex(TM) articulating stylet or the Portex(TM) intubation stylet by an experienced anesthesiologist. The outcome measures included success or failure to intubate in the first attempt, total intubation time, hemodynamic disturbances, trauma if any and user satisfaction.

Results: The number of patients in whom intubation was successful in the first attempt was significantly higher by using Truflex™ articulating stylet (99.1%) compared to Portex(TM) intubation stylet (90.0%; P-Value = 0.003). User satisfaction grade was significantly better while using Truflex(TM) articulating stylet (8.5 ± 0.88) compared to the Portex(TM) intubation stylet (8.23 ± 0.99; P-Value = 0.035). We did not observe any significant difference in total intubation time, hemodynamic disturbances or trauma.

Conclusions: Storz's C-Mac D-blade(TM) videolaryngoscope provides grade I Cormack and Lehane's glottic view in 99.1% patients. First attempt successful tracheal intubation and user satisfaction significantly improved by Truflex(TM) articulating stylet compared to the Portex(TM) intubation stylet.

Citing Articles

New Devices, Innovative Technologies, and Non-Standard Techniques for Airway Management: A Narrative Review.

Gaszynski T, Gomez-Rios M, Serrano-Moraza A, Sastre J, Lopez T, Ratajczyk P Healthcare (Basel). 2023; 11(18).

PMID: 37761667 PMC: 10650429. DOI: 10.3390/healthcare11182468.

References
1.
Kaplan M, Hagberg C, Ward D, Brambrink A, Chhibber A, Heidegger T . Comparison of direct and video-assisted views of the larynx during routine intubation. J Clin Anesth. 2006; 18(5):357-62. DOI: 10.1016/j.jclinane.2006.01.002. View

2.
Cormack R, Lehane J . Difficult tracheal intubation in obstetrics. Anaesthesia. 1984; 39(11):1105-11. View

3.
Piepho T, Fortmueller K, Heid F, Schmidtmann I, Werner C, Noppens R . Performance of the C-MAC video laryngoscope in patients after a limited glottic view using Macintosh laryngoscopy. Anaesthesia. 2011; 66(12):1101-5. DOI: 10.1111/j.1365-2044.2011.06872.x. View

4.
Al-Qasmi A, Al-Alawi W, Malik A, Manzoor Khan R, Kaul N . Assessment of Truflex articulating stylet versus conventional rigid Portex stylet as an intubation guide with the D-blade of C-Mac videolaryngoscope during elective tracheal intubation: study protocol for a randomized controlled trial. Trials. 2013; 14:298. PMC: 3848553. DOI: 10.1186/1745-6215-14-298. View

5.