» Articles » PMID: 26702377

Histogram Analysis with Automated Extraction of Brain-tissue Region from Whole-brain CT Images

Overview
Journal Springerplus
Date 2015 Dec 25
PMID 26702377
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

To determine whether an automated extraction of the brain-tissue region from CT images is useful for the histogram analysis of the brain-tissue region was studied. We used the CT images of 11 patients. We developed an automatic brain-tissue extraction algorithm. We evaluated the similarity index of this automated extraction method relative to manual extraction, and we compared the mean CT number of all extracted pixels and the kurtosis and skewness of the distribution of CT numbers of all extracted pixels from the automated and manual extractions. The similarity index was 0.93. The mean CT number and the kurtosis and skewness from the automated extraction were 35.0 Hounsfield units, 0.63, and 0.51, respectively, and were equivalent to those from the manual extraction (35.4 Hounsfield units, 0.59, and 0.46, respectively). The automated extraction of the brain-tissue region from whole-brain CT images was useful for histogram analysis of the brain-tissue region.

Citing Articles

Fat quantification of the rotator cuff muscles using CT histogram analysis in comparison with Dixon MRI sequence.

Oh J, Yoo H, Chae H, Choi J, Hong S Br J Radiol. 2023; 96(1150):20220817.

PMID: 37660371 PMC: 10546432. DOI: 10.1259/bjr.20220817.


CT Hounsfield unit and histogram analysis for differentiation of recent versus remote vertebral compression fractures.

Ryoo C, Chai J, Hong S, Choi J, Yoo H, Chae H Br J Radiol. 2021; 94(1128):20210941.

PMID: 34538076 PMC: 8631025. DOI: 10.1259/bjr.20210941.

References
1.
Shen S, Szameitat A, Sterr A . Detection of infarct lesions from single MRI modality using inconsistency between voxel intensity and spatial location--a 3-D automatic approach. IEEE Trans Inf Technol Biomed. 2008; 12(4):532-40. DOI: 10.1109/TITB.2007.911310. View

2.
Sakai N, Mishima M, Nishimura K, Itoh H, Kuno K . An automated method to assess the distribution of low attenuation areas on chest CT scans in chronic pulmonary emphysema patients. Chest. 1994; 106(5):1319-25. DOI: 10.1378/chest.106.5.1319. View

3.
DeLeo J, Schwartz M, Creasey H, Cutler N, Rapoport S . Computer-assisted categorization of brain computerized tomography pixels into cerebrospinal fluid, white matter, and gray matter. Comput Biomed Res. 1985; 18(1):79-88. DOI: 10.1016/0010-4809(85)90008-4. View

4.
Maksimovic R, Stankovic S, Milovanovic D . Computed tomography image analyzer: 3D reconstruction and segmentation applying active contour models--'snakes'. Int J Med Inform. 2000; 58-59:29-37. DOI: 10.1016/s1386-5056(00)00073-3. View

5.
Best A, Lynch A, Bozic C, Miller D, Grunwald G, Lynch D . Quantitative CT indexes in idiopathic pulmonary fibrosis: relationship with physiologic impairment. Radiology. 2003; 228(2):407-14. DOI: 10.1148/radiol.2282020274. View