Rationale: On January 6, 2005 a train derailment led to an estimated 54,915-kg release of chlorine at a local textile mill in Graniteville, South Carolina.

Objectives: We used the employee health spirometry records of the textile to identify enduring effects of chlorine gas exposure resulting from the incident on the lung function of workers employed at the textile mill.

Methods: Spirometry records from 1,807 mill workers (7,332 observations) were used from 4 years before and 18 months after the disaster. Longitudinal analysis using marginal regression models produced annual population mean estimates for FEV1, FVC, and FEV1/FVC ratio. Covariate adjustment was made for sex, age, smoking, height, season tested, technician, obesity, season × year interactions, and smoker × year interactions. The increased prevalence of mill workers having accelerated FEV1 decline was also evaluated after the chlorine spill.

Measurements And Main Results: In the year of the accident, we observed a significant reduction in mean FEV1 (-4.2% predicted; P = 0.019) when compared with the year before the incident. In the second year, partial recovery in the mean FVC % predicted level was seen, but the cohort's average FEV1/FVC ratio continued to decrease over time. Severe annual FEV1 decline was most prevalent in the year of the accident, and independent of mill worker smoking status.

Conclusions: The Graniteville mill worker cohort revealed significant reductions in lung function immediately after the chlorine incident. Improvement was seen in the second year; but the proportion of mill workers experiencing accelerated FEV1 annual decline significantly increased in the 18 months after the chlorine incident.

Citing Articles

Recapitulation of human pathophysiology and identification of forensic biomarkers in a translational model of chlorine inhalation injury.

Achanta S, Gentile M, Albert C, Schulte K, Pantazides B, Crow B Am J Physiol Lung Cell Mol Physiol. 2024; 326(4):L482-L495.

PMID: 38318664 PMC: 11281795. DOI: 10.1152/ajplung.00162.2023.


Clinical Features and Outcomes of Acute Chlorine Gas Inhalation; a Brief Report.

Ejaz T, Saadia S, Akhlaq S, Aziz A, Ahmed M, Siddiqui A Arch Acad Emerg Med. 2022; 10(1):e15.

PMID: 35402997 PMC: 8986491. DOI: 10.22037/aaem.v10i1.1448.


Halogen-Induced Chemical Injury to the Mammalian Cardiopulmonary Systems.

Addis D, Aggarwal S, Lazrak A, Jilling T, Matalon S Physiology (Bethesda). 2021; 36(5):272-291.

PMID: 34431415 PMC: 8807065. DOI: 10.1152/physiol.00004.2021.


Effects of Chlorine Gas Exposure and Associated Factors on Spirometric Parameters in Detergent Industry Workers: a Four-Year Cross-Sectional Study.

Malek F, Shomali A, Mirmohammadkhani M, Mansori K, Pahlevan D Tanaffos. 2021; 20(1):43-50.

PMID: 34394369 PMC: 8355941.


Hyaluronan and halogen-induced airway hyperresponsiveness and lung injury.

Lazrak A, Song W, Zhou T, Aggarwal S, Jilling T, Garantziotis S Ann N Y Acad Sci. 2020; 1479(1):29-43.

PMID: 32578230 PMC: 7680259. DOI: 10.1111/nyas.14415.


References
1.
Tuck S, Ramos-Barbon D, Campbell H, McGovern T, Karmouty-Quintana H, Martin J . Time course of airway remodelling after an acute chlorine gas exposure in mice. Respir Res. 2008; 9:61. PMC: 2531104. DOI: 10.1186/1465-9921-9-61. View

2.
Martin J, Campbell H, Iijima H, Gautrin D, Malo J, Eidelman D . Chlorine-induced injury to the airways in mice. Am J Respir Crit Care Med. 2003; 168(5):568-74. DOI: 10.1164/rccm.200201-021OC. View

3.
Arrighi H, Hertz-Picciotto I . The evolving concept of the healthy worker survivor effect. Epidemiology. 1994; 5(2):189-96. DOI: 10.1097/00001648-199403000-00009. View

4.
Janssens J, Pache J, Nicod L . Physiological changes in respiratory function associated with ageing. Eur Respir J. 2000; 13(1):197-205. DOI: 10.1034/j.1399-3003.1999.13a36.x. View

5.
Hankinson J, Odencrantz J, Fedan K . Spirometric reference values from a sample of the general U.S. population. Am J Respir Crit Care Med. 1999; 159(1):179-87. DOI: 10.1164/ajrccm.159.1.9712108. View