» Articles » PMID: 26659827

Laparoscopic Microwave Thermosphere Ablation of Malignant Liver Tumors: An Analysis of 53 Cases

Overview
Journal J Surg Oncol
Date 2015 Dec 15
PMID 26659827
Citations 15
Authors
Affiliations
Soon will be listed here.
Abstract

Background And Objectives: Microwave thermosphere ablation (MTA) is a new technology that is designed to create spherical zones of ablation using a single antenna. The aim of this study is to assess the results of MTA in a large series of patients.

Methods: This was a prospective study assessing the use of MTA in patients with malignant liver tumors. The procedures were done mostly laparoscopically and ablation zones created were assessed for completeness of tumor response, spherical geometry and recurrence on tri-phasic CT scans done on follow-up.

Results: There were a total of 53 patients with an average of 3 tumors measuring 1.5 cm. Ablations were performed laparoscopically in all but eight patients. Morbidity was 11.3% (n = 6), and mortality zero. On postoperative scans, there was 99.3% tumor destruction. Roundness indices A, B, and transverse were 1.1, 1.0, and 0.9, respectively. At a median follow-up of 4.5 months, incomplete ablation was seen in 1 of 149 lesions treated (0.7%) and local tumor recurrence in 1 lesion (0.7%).

Conclusions: The results of this series confirm the safety and feasibility of MTA technology. The 99.3% rate of complete tumor ablation and low rate of local recurrence at short-term follow up are promising.

Citing Articles

Thermal-responsive activation of engineered bacteria to trigger antitumor immunity post microwave ablation therapy.

Wu Y, Liu B, Yan Y, Gong C, Wang K, Liu N Nat Commun. 2024; 15(1):10503.

PMID: 39627266 PMC: 11614905. DOI: 10.1038/s41467-024-54883-x.


HPB ultrasound guidance techniques - Targeting.

Strand M, Iannitti D Surg Open Sci. 2024; 19:50-62.

PMID: 38585037 PMC: 10995864. DOI: 10.1016/j.sopen.2024.02.013.


Comparative Study of Ablation Zone of EMPRINT HP Microwave Device with Contemporary 2.4 GHz Microwave Devices in an Ex Vivo Porcine Liver Model.

Hui T, How G, Chim M, Pua U Diagnostics (Basel). 2023; 13(16).

PMID: 37627962 PMC: 10453042. DOI: 10.3390/diagnostics13162702.


Comparison of Ablation Volume Between Emprint and Mimapro Systems for Hepatocellular Carcinoma -A Preliminary Study.

Ishikawa T, Hasegawa I, Hirosawa H, Honmou T, Sakai N, Igarashi T J Hepatocell Carcinoma. 2023; 10:979-985.

PMID: 37377842 PMC: 10292608. DOI: 10.2147/JHC.S412642.


Microwave Ablation of Liver, Kidney and Lung Lesions: One-Month Response and Manufacturer's Charts' Reliability in Clinical Practice.

Frandon J, Akessoul P, Kammoun T, Dabli D, de Forges H, Beregi J Sensors (Basel). 2022; 22(11).

PMID: 35684594 PMC: 9182645. DOI: 10.3390/s22113973.