» Articles » PMID: 26658566

No Differences in Functional Results and Quality of Life After Single-radius or Multiradius TKA

Overview
Publisher Wiley
Date 2015 Dec 15
PMID 26658566
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: The main objective of this study was to compare the functional results and the impact on quality of life after a single-radius or a multiradius TKA implantation. The secondary objectives were to compare range of motion, satisfaction and the ability to perform daily life activities with both types of implant. It was hypothesized that the single-radius TKA would lead to better functional results and better quality of life than the multiradius TKA.

Methods: This is a prospective non-randomized study that included 250 cases of a single-radius TKA and 224 of a multiradius posterior-stabilized TKA implanted with the same surgical and rehabilitation protocol.

Results: In the 1- and 5-year follow-up, we found similar knee KSS scores (89.7 ± 12.1 in the multiradius group and 90.3 ± 11.7 in the single-radius group) and functional KSS scores (78.6 ± 21.4 in the multiradius group and 75.8 ± 20.9 in the single-radius group). The pain and the Physical SF-36 scores were also similar. Range of motion (112° ± 12° in the multiradius group and 112 ± 12° in the single-radius group), patients' satisfaction and the ability to perform daily life activities were also similar in both groups.

Conclusion: The use of a single-radius or a multiradius posterior-stabilized knee prosthesis can improve the function of the knee and the patients' quality of life in a similar way at the short-term and midterm follow-up. Moreover, range of motion, patient satisfaction and the ability to perform daily life activities are similar with both types of prosthesis. As both types of prosthesis can improve the function and quality of life of the patients in a similar way, the sagittal radius of the femoral component should not be considered the main factor when choosing the model of TKA.

Level Of Evidence: Therapeutic study: Prospective comparative study, Level II.

Citing Articles

Satisfaction after total knee replacement for osteoarthritis is usually high, but what are we measuring? A systematic review.

Klem N, Kent P, Smith A, Dowsey M, Fary R, Schutze R Osteoarthr Cartil Open. 2022; 2(1):100032.

PMID: 36474554 PMC: 9718338. DOI: 10.1016/j.ocarto.2020.100032.


Comparison of Single-Radius with Multiple-Radius Femur in Total Knee Arthroplasty: A Meta-Analysis of Prospective Randomized Controlled Trials.

Lei T, Jiang Z, Qian H, Backstein D, Lei P, Hu Y Orthop Surg. 2022; 14(9):2085-2095.

PMID: 35924690 PMC: 9483041. DOI: 10.1111/os.13391.


Sagittal radius of curvature, trochlea design and ultracongruent insert in total knee arthroplasty.

Ng J, Bloch B, James P EFORT Open Rev. 2019; 4(8):519-524.

PMID: 31538002 PMC: 6719604. DOI: 10.1302/2058-5241.4.180083.


Excellent 10-year patient-reported outcomes and survival in a single-radius, cruciate-retaining total knee arthroplasty.

Scott C, Bell K, Ng R, MacDonald D, Patton J, Burnett R Knee Surg Sports Traumatol Arthrosc. 2018; 27(4):1106-1115.

PMID: 30276434 PMC: 6435607. DOI: 10.1007/s00167-018-5179-9.


A Systematic Review of Clinical Functional Outcomes After Medial Stabilized Versus Non-Medial Stabilized Total Knee Joint Replacement.

Young T, Dowsey M, Pandy M, Choong P Front Surg. 2018; 5:25.

PMID: 29696144 PMC: 5905240. DOI: 10.3389/fsurg.2018.00025.


References
1.
Molt M, Ljung P, Toksvig-Larsen S . Does a new knee design perform as well as the design it replaces?. Bone Joint Res. 2013; 1(12):315-23. PMC: 3626188. DOI: 10.1302/2046-3758.112.2000064. View

2.
AHLBACK S . Osteoarthrosis of the knee. A radiographic investigation. Acta Radiol Diagn (Stockh). 1968; :Suppl 277:7-72. View

3.
Ares O, Castellet E, Macule F, Leon V, Montanez E, Freire A . Translation and validation of 'The Knee Society Clinical Rating System' into Spanish. Knee Surg Sports Traumatol Arthrosc. 2013; 21(11):2618-24. DOI: 10.1007/s00167-013-2412-4. View

4.
Wang H, Simpson K, Ferrara M, Chamnongkich S, Kinsey T, Mahoney O . Biomechanical differences exhibited during sit-to-stand between total knee arthroplasty designs of varying radii. J Arthroplasty. 2006; 21(8):1193-9. DOI: 10.1016/j.arth.2006.02.172. View

5.
Kotani A, Yonekura A, Bourne R . Factors influencing range of motion after contemporary total knee arthroplasty. J Arthroplasty. 2005; 20(7):850-6. DOI: 10.1016/j.arth.2004.12.051. View