» Articles » PMID: 26434767

Rapid Low Dose Electron Tomography Using a Direct Electron Detection Camera

Overview
Journal Sci Rep
Specialty Science
Date 2015 Oct 6
PMID 26434767
Citations 11
Authors
Affiliations
Soon will be listed here.
Abstract

We demonstrate the ability to record a tomographic tilt series containing 3487 images in only 3.5 s by using a direct electron detector in a transmission electron microscope. The electron dose is lower by at least one order of magnitude when compared with that used to record a conventional tilt series of fewer than 100 images in 15-60 minutes and the overall signal-to-noise ratio is greater than 4. Our results, which are illustrated for an inorganic nanotube, are important for ultra-low-dose electron tomography of electron-beam-sensitive specimens and real-time dynamic electron tomography of nanoscale objects with sub-ms temporal resolution.

Citing Articles

Native state structural and chemical characterisation of Pickering emulsions: A cryo-electron microscopy study.

Fernandez Ainaga D, Roncal-Herrero T, Ilett M, Aslam Z, Cheng C, Hitchcock J J Microsc. 2025; 298(1):92-105.

PMID: 39887717 PMC: 11891983. DOI: 10.1111/jmi.13391.


Seeing the Supracolloidal Assemblies in 3D: Unraveling High-Resolution Structures Using Electron Tomography.

Nonappa ACS Mater Au. 2024; 4(3):238-257.

PMID: 38737122 PMC: 11083119. DOI: 10.1021/acsmaterialsau.3c00067.


In-situ heating-and-electron tomography for materials research: from 3D (in-situ 2D) to 4D (in-situ 3D).

Hata S, Ihara S, Saito H, Murayama M Microscopy (Oxf). 2024; 73(2):133-144.

PMID: 38462986 PMC: 11000667. DOI: 10.1093/jmicro/dfae008.


Five-second STEM dislocation tomography for 300 nm thick specimen assisted by deep-learning-based noise filtering.

Zhao Y, Koike S, Nakama R, Ihara S, Mitsuhara M, Murayama M Sci Rep. 2021; 11(1):20720.

PMID: 34702955 PMC: 8548491. DOI: 10.1038/s41598-021-99914-5.


Lanthanide-Based Nanosensors: Refining Nanoparticle Responsiveness for Single Particle Imaging of Stimuli.

Casar J, McLellan C, Siefe C, Dionne J ACS Photonics. 2021; 8(1):3-17.

PMID: 34307765 PMC: 8297747. DOI: 10.1021/acsphotonics.0c00894.


References
1.
Ferrer M, Martin-Jaular L, De Niz M, Khan S, Janse C, Calvo M . Imaging of the spleen in malaria. Parasitol Int. 2013; 63(1):195-205. DOI: 10.1016/j.parint.2013.08.014. View

2.
Deptuch G, Besson A, Rehak P, Szelezniak M, Wall J, Winter M . Direct electron imaging in electron microscopy with monolithic active pixel sensors. Ultramicroscopy. 2007; 107(8):674-84. DOI: 10.1016/j.ultramic.2007.01.003. View

3.
Orsholm , Csillag , Borglund . High-detective-quantum-efficiency fast-electron detector for electron energy loss spectroscopy. Micron. 2000; 31(4):441-50. DOI: 10.1016/s0968-4328(99)00122-5. View

4.
Jinnai H, Tsuchiya T, Motoki S, Kaneko T, Higuchi T, Takahara A . Transmission electron microtomography in soft materials. Microscopy (Oxf). 2012; 62(2):243-58. DOI: 10.1093/jmicro/dfs070. View

5.
Baumeister W, Grimm R, Walz J . Electron tomography of molecules and cells. Trends Cell Biol. 1999; 9(2):81-5. DOI: 10.1016/s0962-8924(98)01423-8. View