Comparison of Magnetic Wire Navigation with the Conventional Wire Technique for Percutaneous Coronary Intervention of Chronic Total Occlusions: a Randomised, Controlled Study

Overview
Journal Heart Vessels
Date 2015 Sep 16
PMID 26369660
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

Wire crossing of a chronic total coronary occlusion (CTO) is time consuming and limited by the amount of contrast agent and time of radiation exposure. Magnetic wire navigation (MWN) might accelerate wire crossing by maintaining a coaxial vessel orientation. This study compares MWN with the conventional approach for recanalization of CTOs. Forty symptomatic patients with CTO were randomised to MWN (n = 20) or conventional approach (n = 20) for antegrade crossing of the occlusion. In the intention-to-treat analysis, MWN showed a shorter crossing time (412 versus 1131 s; p = 0.001), and, consequently, lower usage of contrast agent (primary endpoint 42 versus 116 ml; p = 0.01), and lower radiation exposure (dose-area product: 29 versus 80 Gy*cm(2); p = 0.002) during wire crossing compared to the conventional approach. Accordingly, in the per-protocol analysis, the wire-crossing rate was, in trend, higher using the conventional approach (17 of 31) compared to MWN (9 of 28; p = 0.08). The use of MWN for revascularisation of CTOs is feasible and reduces crossing time, use of contrast agent, and radiation exposure. However, due to a broader selection of wires, the conventional approach enables wire crossing in cases failed by MWN and seems to be the more successful choice.

Citing Articles

Application of a rapid exchange extension catheter technique in type B2/C nonocclusive coronary intervention a transradial approach.

Wang H, Lu W, Gao Z, Xie Y, Hao J, Liu J World J Clin Cases. 2021; 9(12):2751-2762.

PMID: 33969058 PMC: 8058684. DOI: 10.12998/wjcc.v9.i12.2751.


Magnetic navigation system for percutaneous coronary intervention: A meta-analysis.

Qi Z, Wu B, Luo X, Zhu J, Shi H, Jin B Medicine (Baltimore). 2016; 95(29):e4216.

PMID: 27442645 PMC: 5265762. DOI: 10.1097/MD.0000000000004216.

References
1.
Safley D, House J, Marso S, Grantham J, Rutherford B . Improvement in survival following successful percutaneous coronary intervention of coronary chronic total occlusions: variability by target vessel. JACC Cardiovasc Interv. 2009; 1(3):295-302. DOI: 10.1016/j.jcin.2008.05.004. View

2.
Chambers C, Fetterly K, Holzer R, Lin P, Blankenship J, Balter S . Radiation safety program for the cardiac catheterization laboratory. Catheter Cardiovasc Interv. 2011; 77(4):546-56. DOI: 10.1002/ccd.22867. View

3.
Miller D, Hilohi C, Spelic D . Patient radiation doses in interventional cardiology in the U.S.: advisory data sets and possible initial values for U.S. reference levels. Med Phys. 2012; 39(10):6276-86. DOI: 10.1118/1.4754300. View

4.
Di Mario C, Werner G, Sianos G, Galassi A, Buttner J, Dudek D . European perspective in the recanalisation of Chronic Total Occlusions (CTO): consensus document from the EuroCTO Club. EuroIntervention. 2009; 3(1):30-43. View

5.
Atmakuri S, Lev E, Alviar C, Ibarra E, Raizner A, Solomon S . Initial experience with a magnetic navigation system for percutaneous coronary intervention in complex coronary artery lesions. J Am Coll Cardiol. 2006; 47(3):515-21. DOI: 10.1016/j.jacc.2005.11.017. View