» Articles » PMID: 26319771

The Reliability of Ultrasound Measurements of the Median Nerve at the Carpal Tunnel Inlet

Overview
Journal J Hand Surg Am
Publisher Elsevier
Date 2015 Aug 31
PMID 26319771
Citations 16
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To determine the interrater and intra-rater reliability of ultrasound (US) measurement of the cross-sectional area (CSA) of the median nerve at the carpal tunnel inlet.

Methods: Three examiners of varying levels of experience performed US measurements of the CSA of the median nerve at the carpal tunnel inlet of both wrists of 11 healthy volunteers. Each examiner was blinded to the measurements of the other examiners. The measurements were repeated 2 weeks later in random order to test intra-rater reliability. The Lin concordance correlation coefficient (LCCC) for interrater and intra-rater reliability was calculated.

Results: The overall inter-rater LCCC was 0.59 (95% confidence interval [CI], 0.41-0.73). Intra-rater LCCC varied based on examiner experience. The senior author had an intra-rater LCCC of 0.91 (95% CI, 0.80-0.96), the hand fellow had an intra-rater LCCC of 0.45 (95% CI, 0.17-0.66), and the first-year resident had an intra-rater LCCC of 0.78 (95% CI, 0.55-0.90).

Conclusions: There is moderate agreement among examiners of varying levels of experience when measuring the CSA of the median nerve at the carpal tunnel inlet. Examiner experience affected intra-rater reliability of measurements; an experienced examiner had nearly perfect agreement compared with moderate agreement for less experienced examiners.

Citing Articles

Diagnostic Dilemmas in Carpal Tunnel Syndrome and Cervical Spine Disorders: A Comprehensive Review.

Hara Y, Yoshii Y Diagnostics (Basel). 2025; 15(2).

PMID: 39857006 PMC: 11764257. DOI: 10.3390/diagnostics15020122.


Education Research: Feasibility, Reliability and Educational Value of Neuromuscular Ultrasound Training in a Canadian Neurology Residency Program: A Pilot Study.

Alzaabi A, Chaggar G, Hussain M, Daniels V, Beecher G Neurol Educ. 2024; 3(4):e200166.

PMID: 39391798 PMC: 11466532. DOI: 10.1212/NE9.0000000000200166.


3D fascicular reconstruction of median and ulnar nerve: initial experience and comparison between high-resolution ultrasound and MR microscopy.

Pusnik L, Lechner L, Sersa I, Cvetko E, Haas P, Jengojan S Eur Radiol Exp. 2024; 8(1):100.

PMID: 39196445 PMC: 11358559. DOI: 10.1186/s41747-024-00495-5.


Reliability of Ultrasound Measurements of the Median Nerve in Asymptomatic Subjects Using a Handheld Device.

Alfuraih A, Aldahlawi R, Habib Y, Alhowimel A, Bedewi M Sensors (Basel). 2024; 24(11).

PMID: 38894235 PMC: 11175092. DOI: 10.3390/s24113444.


Characteristics of Patients with Clinical Signs and Symptoms of Carpal Tunnel Syndrome but Negative Diagnostic Testing.

Latario L, Fowler J Plast Reconstr Surg Glob Open. 2024; 12(5):e5816.

PMID: 38752222 PMC: 11095960. DOI: 10.1097/GOX.0000000000005816.